10
Load modulator operation
The load modulator will take into account the household consumption and
adjust the power demand to achieve the fullest recharge in the shortest time
possible without exceeding the rated power. In VIARIS COMBI with two outlets,
the load modulator distributes the available energy between the two outlets.
Couple/clamp the
TMC100
transformer (included) to the phase conductor (L)
so that it measures the total consumption of the installation, including that of
the VIARIS COMBI.
RESPECT THE SENSE OF THE CURRENT INDICATED ON THE
TMC100
LABEL.
TMC100
I máx 100 A
L
I máx 100 A
HOUSEHOLD
METER
HOU
CHARGER
HOU
CHARGER
HOUSEHOLD
METER
VIARIS COMBI