Orbis CALORAMA Installation And Operating Manual Download Page 2

1

CALORAMA/COMFORT VIEW SERIES DIRECT VENT WALL FURNACE

INSTALLATION AND OPERATING MANUAL

SECTION I  -  Introduction and Safety Information
Introduction
Basic Description
Qualified Service Agency
Safety Rules
Safety Information for Users of Propane / L.P. Gas
Propane / L.P. Gas odor Warning
CALORAMA/COMFORT VIEW (CCV) HEATER SPECIFICATIONS

SECTION II  –  Installing Your Orbis ( CCV ) Direct Vent Space Heater
Unpack the Heater
Locating the Orbis Calorama/Comfort View Series Space Heaters

Figure 1: Outside Clearances to the Vent Cap             
Figure 2: Clearances for Mounting the Heater Itself
Table 2: Minimum Clearances Required for Mounting

Mounting Template

Figure 3: ALL MODELS – Unit Mounting Instructions
Figure 4: Unit Mounting Template Position
Figure 5: Wall Mounting Plate

SECTION III  -  Vent, Wall Plate and Unit Installation
Unpack the Vent Assembly
Prepare for Installation

Figure 6: Exploded Side View of Vent Installation

Vent and Wall Plate Installation

Figure 7: Vent Kit Assembly                   
Figure 8: Vent Cap as seen from the Outside

Connect Gas Piping
Gas Supply
Pressure Testing of the Gas Supply Piping System

Figure 9: Guidelines for Gas Piping Connections 

Check for Gas Leaks
Installing the Unit Cover
Lighting the Unit

Figure 10: Lighting Instructions

Adjusting the Thermostat

SECTION IV  -  Maintenance Instructions
Maintenance Instructions (General)
Maintenance Instructions for Calorama/Comfort View Series Heaters

Figure 11: Flame Pattern Calorama/Comfort View Series

SECTION V  -  Troubleshooting Guide
SECTION VI  -  Replacement Parts Guide
SECTION VII  - Limited Warranty
SECTION VIII  -  Blower Option

  

         

INDEX

Page 2
Page 2
Page 2
Page 3
Page 4
Page 5
Page 5

Page 6
Page 6
Page 7
Page 8
Page 8
Page 8
Page 9

Page 10
Page 10

Page 11
Page 11
Page 11
Page 12
Page 13
Page 13
Page 14
Page 14
Page 14
Page 15
Page 15
Page 16
Page 16
Page 16
Page 17

Page 18

Pages 18-20

Page 20

Pages 21-23
Pages 24-25
Pages 26-27
Pages 28-29

Summary of Contents for CALORAMA

Page 1: ...ORTED BY The Gas Appliance Company Inc FLORIDA US of A www orbisheat com WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage person...

Page 2: ...Installation Figure 6 Exploded Side View of Vent Installation Vent and Wall Plate Installation Figure 7 Vent Kit Assembly Figure 8 Vent Cap as seen from the Outside Connect Gas Piping Gas Supply Press...

Page 3: ...rect Vent Wall Furnace Standard CAN 2 32M98 to provide safe trouble free operation throughout the expected life of the unit Any alteration modification or adjustment not specifically mentioned in this...

Page 4: ...the vent assembly supplied with the unit so that harmful gases will not gather inside of the building The vent kit part number for your unit can be found in the exploded parts view at the end of this...

Page 5: ...e immediate action in order to reduce or eliminate the risk of injury and or property damage KNOW AND MAKE SURE OTHERS IN YOUR HOUSEHOLD KNOW THE FOLLOWING PROCEDURES TO TAKE IN THE EVENT OF A PROPANE...

Page 6: ...mm wc 7 178 mm wc 10 254 mm wc 10 254 mm wc 10 254 mm wc 11 279 mm wc 11 279 mm wc 11 279 mm wc 13 330 mm wc 13 330 mm wc 13 330 mm wc 3 8 NPT 3 8 NPT 3 8 NPT 2 51 mm 2 51 mm 2 51 mm 12 305 mm 12 305...

Page 7: ...osing a location for your ORBIS Calorama Comfort View Series Direct Vent Wall Furnace please remember that the Vent Kit supplied with the unit must be installed WITHOUT alteration with the exception o...

Page 8: ...sure regulator provided with this unit C 12 in minimum 12 in minimum 4 ft minimum 4 ft minimum 12 in minimum 3 ft minimum Grade Forced air inlet Mechanical draft vent terminal see 7 8 b Mechanical dra...

Page 9: ...3 The template illustrates all of the openings and mounting holes and their correct location for EACH UNIT The illustration Figure 3 gives you the required dimensional information for mounting the uni...

Page 10: ...shed unit to adjacent combustible materials Figure 3 ALL MODELS Unit Mounting Instructions 8 35 212 mm 1 65 42 mm 11 89 302 mm 12 09 307 mm 10 85 275 5 mm 14 78 375 5mm 7 89 200 5 mm 4 8 121 9 mm 5 12...

Page 11: ...10 Figure 4 Unit Mounting Template Position Figure 5 Wall Mounting Plate ALL MODELS Unit mounting positions Wall mounting positions TEMPLATE...

Page 12: ...ombustion and ventilation air must NEVER be obstructed Prepare for Installation After ensuring that the location you have selected for the installation complies with the requirements outlined in this...

Page 13: ...rotection pipe to pass through without bending In addition make sure that the holes in the inside and outside wall are concentric to one another NOTE Cut the outside hole slightly lower not more than...

Page 14: ...he vent cap is securely engaged with the similar sized opening in the rear of the unit Make sure the exhaust vent pipe remains engaged in its position in the vent cap The air inlet pipe must also slid...

Page 15: ...ust be installed in accordance with all applicable building and plumbing codes For Propane Units Gas supply Line Pressure MUST NOT EXCEED 13 IN W C It is recommended that a gas shut off valve be insta...

Page 16: ...e bubbles to form Note any leaks in the piping system Shut off the gas at the shut off valve if installed or at the gas meter of the Propane LP tank serving the structure Fix the leaking joint and re...

Page 17: ...in or turn by hand don t try to repair it call qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Im...

Page 18: ...the most comfort for you Excessively high temperature settings can cause you to constantly readjust the thermostat and lose valuable efficiency WARNING DO NOT OPERATE THIS APPLIANCE WITH THE PILOT MA...

Page 19: ...he back cover Step 4 Carefully examine the interior of the vent pipe If you notice any blockage or obstruction that was not part of the unit when it was installed clean the pipes and prepare them for...

Page 20: ...k on the wall mounting plate Step 8 Reconnect the gas supply Perform the leak test procedure found in the section of this manual titled Check for Gas Leaks on page 14 Step 9 Verify Proper Operation Af...

Page 21: ...d of the front cover leaning about an inch forward push the front cover in and down until the bolts lock into place Slide the overhangs at the upper end of the front cover under the back cover and fix...

Page 22: ...is damaged or wire lead is loose 3 Pilot orifice is clogged 4 Gas Control knob not set properly 5 Improper gas supply SOLUTION 1 No action required will stop after a short period of operation 2 Apply...

Page 23: ...that position is in the center of the pilot flame tip Replace as necessary 3 Wait 5 minutes to allow the heater to cool down then relight 1 Review correct lighting procedures see Figure 10 on page 15...

Page 24: ...as supply SOLUTION 7 Call your gas supplier 1 Adjust thermostat to HI position and modulate down until a proper room temperature rate is attained 2 Average room size heating capacity UNIT Ave Floor Ar...

Page 25: ...24 SECTION VI REPLACEMENT PARTS GUIDE Orbis Calorama Comfort View Series Gas System 2 15 1 3 6 7 8 4 5 9 10 11 12 14 1 A B C D E F 13...

Page 26: ...n Burner Injector CCV III L P 1 35mm CCV 3004P 5 Main Burner Injector Adaptor CCV 5005 6 A Pilot Injector CCV N G 0 25mm 2x CCV 5006N 6 B Pilot Injector CCV L P 0 20mm CCV 5006P 7 Electrode Ceramic CC...

Page 27: ...costs must be borne by the Purchaser Exceptions This warranty will not apply 1 to defects or malfunctioning resulting from failure to properly install operate or maintain the unit in accordance with...

Page 28: ...CE TECHNICIAN OR APPLIANCES SERVICES AND PARTS COMPANY INC ASAP INFORMATION BELOW MANUFACTURED BY ORBIS MERTIG SAIC YERBAL 1200 1607 VILLA ADELINA PROVINCIA DE BUENOS AIRES ARGENTINA IMPORTED BY THE G...

Page 29: ...ide of the unit above the gas valve See figure 13 With the cover still off mount blower into the wall directly under and centered on the unit using the two fastening screws provided See figure 12 for...

Page 30: ...ESCRIPTION PART NUMBER OF PART NUMBER 1 A Blower kit Calorama Comfort View I BK 1 1 B Blower kit Calorama Comfort View II BK 2 1 C Blower kit Calorama Comfort View III BK 3 1 D Blower Fan All Units BK...

Reviews: