Required Materials: 

Orbinox RB Weir Gates are installed by means of Anchor Bolts. Depending on the size and working 
conditions  they  shall be  either  of  the mechanical  or  chemical  type.  Note  that as  standard, anchor 
bolts and construction sealant are not supplied with the weir gate. 

In order to get the expected performance of the anchor bolts, the minimum concrete strength shall 
be 3,000 PSI (20.7 MPa). 

In  order  to  avoid  leakage  between  the  concrete  wall  and  the  frame,  construction  sealant  shall  be 
used. (Sikabond Construction Sealant or equivalent, 200ml per meter of opening perimeter). 

The following table gives a general description of the required anchor bolt types for the different gate 
sizes and pressure conditions. For detailed information about the type, size and quantity of the re-
quired anchor bolts, or any other specific installation notes or materials, please refer to the notes on 
the „General Arrangement Drawing‟.  

RB Size 

Water Pressure 

Anchor Bolt Type  

Recommended (Hilti 

or equivalent) 

RB - 3 Side Sealed 

6” x 6”  - 80” x 80” 

(150mm x 150mm - 2000mm x 2000mm) 

Seating and Un-Seating 

(Bi-Directional) 

Stud Type Mechanical Anchor Bolts 

 

Hilti „Kwik 3‟ 

 

RB - 4 Side Sealed 

6” x 6”  - 48” x 48” 

(150mm x 150mm - 1200mm x 1200mm) 

Seating and Un-Seating 

(Bi-Directional) 

Stud Type Mechanical Anchor Bolts 

and 

Bolt Type Mechanical Anchor Bolts 

Hilti „Kwik 3‟ 

and 

Hilti „HSL‟ 

RB - 4 Side Sealed 

52” x 52” - 80” x 80” 

(1300mm x 1300mm - 2000mm x 2000mm) 

Seating and Un-Seating 

(Bi-Directional) 

Chemical Anchor Bolts 

Hilti „HVU‟ 

Summary of Contents for RB Weir Gate

Page 1: ...Installation Operation and Maintenance Manual RB Weir Gate...

Page 2: ...LATION OPERATION AND MAINTENANCE MANUAL MODEL RB WEIR GATES INDEX Introduction Handling and Storage Installation Weir Gate installation Concrete Wall Mounted Concrete Round Manhole Wall Mounted Wall T...

Page 3: ...y the customer prior to the production of the weir gate Orbinox as sumes no responsibility or liability if the slide gate is not installed operated and maintained in strict accordance to the procedure...

Page 4: ...truction sealant shall be used Sikabond Construction Sealant or equivalent 200ml per meter of opening perimeter The following table gives a general description of the required anchor bolt types for th...

Page 5: ...ncrete construction shall be flat level and plumb and shall be in accordance to ACI 117 06 standard If necessary use non shrink grout in order to meet the specified standard Concrete wall surface shal...

Page 6: ...ant application Sikabond or equivalent In order to avoid leakage between the frame and the wall construction sealant shall be applied on the frame Remove the weir gate from the wall first remove the n...

Page 7: ...ll and install the rest of the anchor bolts see Figure 5 CAUTION If the weir gate is not completely in contact with the wall do not over tighten the an chor bolts Over tightening may bend or distort t...

Page 8: ...ll be used Sikabond Con struction Sealant or equivalent 200ml per meter of opening perimeter For detailed information about the size and quantity of the required bolts or any other specific installati...

Page 9: ...2 Insert all stem guides from the top of the stem extension when applicable Align stem extension and especially make sure that it is aligned with the vertical axis of the opening see Figure 7 The maxi...

Page 10: ...A ORBINOX SPAIN ORBINOX UK ORBINOX FRANCE ORBINOX GERMANY ORBINOX INDIA ORBINOX CHINA WWW ORBINOX COM OBXC 05 2010 10 05 2010 Edition Revision INSTALLATION OPERATION AND MAINTENANCE MANUAL MODEL RB WE...

Page 11: ...tion before cycling the weir gate Manu ally open the gate approximately 5 before the initial electric motor operation Check the motor rotation to assure proper direction of the slide travel according...

Page 12: ...and in the guides Check the seals and make sure they are not damaged Seals shall be replaced if damaged See section Maintenance Seal Replacement for detailed procedures about seal replacement Seals s...

Page 13: ...s item 4 UHMWPE guides item 5 and frame Proceed with caution as major components of the gate are no longer se cured Step 3 Remove frame guides item 4 UHMWPE guides item 5 slide item 7 yoke item 6 and...

Page 14: ...DA ORBINOX USA ORBINOX SPAIN ORBINOX UK ORBINOX FRANCE ORBINOX GERMANY ORBINOX INDIA ORBINOX CHINA WWW ORBINOX COM OBXC 05 2010 14 05 2010 Edition Revision INSTALLATION OPERATION AND MAINTENANCE MANUA...

Page 15: ...MAINTENANCE SEAL REPLACEMENT 49 X49 TO 80 X80 Step 1 Start from the open position Step 2 Unscrew bolts item 1 with caution as the slide is no longer secured Step 3 Unscrew bolts and nuts items 10 and...

Page 16: ...ADA ORBINOX USA ORBINOX SPAIN ORBINOX UK ORBINOX FRANCE ORBINOX GERMANY ORBINOX INDIA ORBINOX CHINA WWW ORBINOX COM OBXC 05 2010 16 05 2010 Edition Revision INSTALLATION OPERATION AND MAINTENANCE MANU...

Page 17: ...install the weir gate clean the wall and apply a new layer of construction sealant Loose anchor bolts Tighten anchor bolts Incorrect anchor bolts Check the General Arrangement Drawing and make sure th...

Reviews: