Description
Setting
Alarm Input
DIP Switch
Position 1 - 6
All alarm cables inputs
provide monitoring.
OFF
Not Used.
ON
------
5
Not Used, set to ON.
OFF
Not Used, set to OFF.
ON
------
6
Not Used.
OFF
6. Re install the alarm card using
Procedure — Replacing the PDP Alarm Card
7. Reconnect all power sources to the PDP.
Replacing T1200 AS Hard Drive
The T1200 application server must be operated with the top cover in place to ensure proper cooling.
A non-skid surface or a stop behind the server may be needed to prevent the server from sliding on
the work surface.
Up to three hot-swappable hard drives can be installed in the Tekelec 1200 application server. The
front bezel must be removed to add or replace a hard drive.
Caution: If installing fewer than three hard drives, the empty bays must be populated
with drive trays that have baffles in them to maintain proper system cooling.
Note: The Tekelec 1200 application server does not support all SAS hard drives. Use only
Tekelec-approved hard drives.
To replace a T1200 AS hard drive, perform these procedures in the following order:
1.
Procedure — Preparing a Hard Drive for Removal
2.
Procedure — Removing the Front Bezel
3.
Procedure — Removing a Hard Drive
4.
Procedure — Installing a Hard Drive
5.
Procedure — Replacing the Front Bezel
6.
Procedure — Preparing a Hard Drive After Installation
Procedure — Preparing a Hard Drive for Removal
When a disk has been identified for removal, the bad disk must be removed from mirroring.
Note: The drive bays are numbered from right (drive 0, sda) to left (drive 2, sdc).
Before removing the bad disk, use the following command for the failed disk:
/usr/TKLC/plat/sbin/failDisk [--force] <disk to be replaced>
48
910-5680-001 Revision F, February 2014
Field Replaceable Units (FRUs)
Platform Maintenance