![Oracle Sun Netra X4270 Service Manual Download Page 137](http://html1.mh-extra.com/html/oracle/sun-netra-x4270/sun-netra-x4270_service-manual_1646169137.webp)
Identify and Remove Faulty DIMMs
■
“DIMM Population Rules” on page 134
■
“DIMM Considerations and Limitations” on page 135
■
“DIMM Rank Classification Labels” on page 136
■
“Identify and Remove Faulty DIMMs” on page 137
■
Identify and Remove Faulty DIMMs
1.
Prepare the server for service.
“Preparing the Server for Component Replacement” on page 75
.
2.
If there are full-length PCIe2 cards installed in PCIe slots 4 and 5, remove the PCI
mezzanine, if necessary.
“Remove the PCI Mezzanine” on page 102
.
3.
Remove the air duct.
“Remove the Air Duct” on page 127
.
4.
When removing DIMMs from slots D4 through D8 next to CPU P0, remove the
media bay assembly.
“Remove the Media Bay Assembly” on page 93
Replacing Motherboard Assembly Components
137
Summary of Contents for Sun Netra X4270
Page 1: ...Sun Netra X4270 Server Service Manual Part No E23171 03 September 2015 ...
Page 2: ......
Page 10: ...10 Sun Netra X4270 Server September 2015 ...
Page 12: ...12 Sun Netra X4270 Server September 2015 ...
Page 36: ...36 Sun Netra X4270 Server September 2015 ...
Page 72: ...72 Sun Netra X4270 Server September 2015 ...
Page 100: ...100 Sun Netra X4270 Server September 2015 ...
Page 224: ...224 Sun Netra X4270 Server September 2015 ...
Page 230: ...WDT W WDT watchdog timers 230 Sun Netra X4270 Server September 2015 ...