Servicing the SPM
These topics describe how to service the SPM.
■
“SPM Firmware and Configuration” on page 131
■
■
■
SPM Firmware and Configuration
System firmware consists of two components, an SP component and a host component. The
SP firmware component is located on the SPM, and the host component is located on the
motherboard. For the server to operate correctly, the firmware in these two components must be
compatible.
When replacing the SPM, you must restore the configuration settings maintained in the SPM.
Before replacing the SPM, save the configuration using the Oracle ILOM backup utility. Refer
to the Oracle ILOM documentation for instructions on backing up and restoring the Oracle
ILOM configuration.
After replacing the SPM, the new SPM firmware component and the existing host
firmware component must be consistent with each other. To ensure that the firmware is
compatible throughout the server, load new system firmware as described in
Related Information
■
Oracle ILOM documentation
■
“Servicing the Motherboard” on page 147
■
■
Servicing the SPM
131
Summary of Contents for SPARC T7-1
Page 1: ...SPARC T7 1 Server Service Manual Part No E54980 06 May 2017 ...
Page 2: ......
Page 9: ...Contents Index 187 9 ...
Page 10: ...10 SPARC T7 1 Server Service Manual May 2017 ...
Page 12: ...12 SPARC T7 1 Server Service Manual May 2017 ...
Page 22: ...22 SPARC T7 1 Server Service Manual May 2017 ...
Page 72: ...72 SPARC T7 1 Server Service Manual May 2017 ...
Page 82: ...82 SPARC T7 1 Server Service Manual May 2017 ...
Page 112: ...112 SPARC T7 1 Server Service Manual May 2017 ...
Page 120: ...120 SPARC T7 1 Server Service Manual May 2017 ...
Page 130: ...130 SPARC T7 1 Server Service Manual May 2017 ...
Page 146: ...146 SPARC T7 1 Server Service Manual May 2017 ...
Page 172: ...172 SPARC T7 1 Server Service Manual May 2017 ...
Page 182: ...182 SPARC T7 1 Server Service Manual May 2017 ...