Determine Which DIMM Is Faulty (LEDs)
Servicing DIMMs
75
■
“Remove a DIMM or DIMM Filler Panel” on page 76
■
Determine Which DIMM Is Faulty (LEDs)
1.
Check that the Service Required LED is lit on the front of the server.
“Front Panel Controls and LEDs” on page 31
.
2.
Check that the Service Required LED is lit on one of the processor modules.
“Processor Module LEDs” on page 61
3.
Remove the PM with the faulty DIMM.
“Remove a Processor Module or Processor Filler Module” on page 63
4.
Locate the DIMM Fault Remind button on the front right corner of the
motherboard.
5.
Verify that the DIMM Fault Remind Power LED next to the button is lit.
An illuminated DIMM Fault Remind Power LED indicates that there is power available to light
the faulty DIMM LED after you have pressed the DIMM Fault Remind button.
Summary of Contents for SPARC T5-8
Page 1: ...Part No E35082 14 November 2015 SPARC T5 8 Server Service Manual ...
Page 2: ......
Page 10: ...10 SPARC T5 8 Server Service Manual November 2015 ...
Page 12: ...12 SPARC T5 8 Server Service Manual November 2015 ...
Page 48: ...48 SPARC T5 8 Server Service Manual November 2015 ...
Page 58: ...58 SPARC T5 8 Server Service Manual November 2015 ...
Page 108: ...108 SPARC T5 8 Server Service Manual November 2015 ...
Page 122: ...122 SPARC T5 8 Server Service Manual November 2015 ...
Page 140: ...140 SPARC T5 8 Server Service Manual November 2015 ...
Page 148: ...148 SPARC T5 8 Server Service Manual November 2015 ...
Page 180: ...180 SPARC T5 8 Server Service Manual November 2015 ...
Page 190: ...190 SPARC T5 8 Server Service Manual November 2015 ...
Page 194: ...194 SPARC T5 8 Server Service Manual November 2015 ...
Page 200: ...200 SPARC T5 8 Server Service Manual November 2015 ...
Page 206: ...206 SPARC T5 8 Server Service Manual November 2015 ...