Determine Which DIMM Is Faulty (FMA)
Servicing DIMMs
73
Related Information
■
“DIMM Configuration Fault Messages” on page 76
■
“Determine Which DIMM Is Faulty (FMA)” on page 73
■
“Determine Which DIMM Is Faulty (LEDs)” on page 75
■
■
“Server Upgrade Process” on page 59
Determine Which DIMM Is Faulty (FMA)
The FMA
fmadm
faulty
command displays current server faults, including DIMM failures.
Type
fmadm
faulty
at the
faultmgmtsp
prompt.
->
start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)?
y
faultmgmtsp>
fmadm faulty
------------------- ------------------------------------ ---------------- ---------
Summary of Contents for SPARC T5-8
Page 1: ...Part No E35082 14 November 2015 SPARC T5 8 Server Service Manual ...
Page 2: ......
Page 10: ...10 SPARC T5 8 Server Service Manual November 2015 ...
Page 12: ...12 SPARC T5 8 Server Service Manual November 2015 ...
Page 48: ...48 SPARC T5 8 Server Service Manual November 2015 ...
Page 58: ...58 SPARC T5 8 Server Service Manual November 2015 ...
Page 108: ...108 SPARC T5 8 Server Service Manual November 2015 ...
Page 122: ...122 SPARC T5 8 Server Service Manual November 2015 ...
Page 140: ...140 SPARC T5 8 Server Service Manual November 2015 ...
Page 148: ...148 SPARC T5 8 Server Service Manual November 2015 ...
Page 180: ...180 SPARC T5 8 Server Service Manual November 2015 ...
Page 190: ...190 SPARC T5 8 Server Service Manual November 2015 ...
Page 194: ...194 SPARC T5 8 Server Service Manual November 2015 ...
Page 200: ...200 SPARC T5 8 Server Service Manual November 2015 ...
Page 206: ...206 SPARC T5 8 Server Service Manual November 2015 ...