Check for Faults
Manufacturer : Oracle Corporation
Name : SPARC T5-1B
Part_Number : 7023631-04
Serial_Number : 1219EK001X
----------------------------------------
Suspect 1 of 1
Fault class : fault.memory.dimm-ue
Certainty : 100%
Affects : /SYS/MB/CM0/CMP/BOB6/CH1/D0
Status : faulted but still in service
FRU
Status : faulty
Location : /SYS/MB/CM0/CMP/BOB6/CH1/D0
Manufacturer : Samsung
Name : 8192MB DDR3 SDRAM DIMM
Part_Number : 07042208,M393B1K70DH0-YK0
Revision : 02
Serial_Number : 00CE0212133341DB80
Chassis
Description : Description associated with fault.memory.dimm-ue
Response : Response associated with fault.memory.dimm-ue
Impact : Impact associated with fault.memory.dimm-ue
Action : Use 'fmadm faulty' to provide a more detailed view of this
event. Action associated with fault.memory.dimm-ue Please
refer to the associated reference document at
http://support.oracle.com/msg/SPSUN4V-8000-F2 for the latest
service procedures and policies regarding this diagnosis.
In this example, a fault is displayed, indicating these details:
■
Date and time of the fault (
2013-01-08/12:13:42
).
■
UUID (
59b2d926-4896-e979-e85c-cfedb5daedf5
), which is unique for every fault.
This is sometimes identified as an Event ID.
■
Message identifier (SPSUN4V-8000-F2), which can be used to obtain
additional fault information.
■
Faulted component, including these details:
34
SPARC T5-1B Server Module Service Manual • February 2019
Summary of Contents for SPARC T5-1B
Page 1: ...SPARC T5 1B Server Module Service Manual Part No E35203 07 February 2019 ...
Page 2: ......
Page 10: ...10 SPARC T5 1B Server Module Service Manual February 2019 ...
Page 16: ...16 SPARC T5 1B Server Module Service Manual February 2019 ...
Page 104: ...104 SPARC T5 1B Server Module Service Manual February 2019 ...
Page 110: ...110 SPARC T5 1B Server Module Service Manual February 2019 ...