If an electrical accident occurs, remove power from the system immediately by unplugging
the chassis.
•
Always disconnect the power from the system when removing a Acme Packet 1100 from
its rack.
•
When disconnecting power:
–
Disconnect the circuit breaker at the rack.
–
Unplug or unscrew the power cords from the power supplies.
•
Use grounded AC power cords that are plugged into grounded electrical outlets.
•
Ensure that the installation facilities have proper grounding systems and include a
grounded rack structure or local grounding bus bar.
•
When installing the Acme Packet 1100 in an equipment rack, always make the ground
connection first and disconnect it last upon uninstallation.
•
Use shielded Category 5e or 6, RJ45 cables for all 10/100/1000 Ethernet connections to
protect the Acme Packet 1100 from potential damage.
•
To avoid making a complete circuit (which causes electrical shock), use only one hand
when working with powered-on electrical equipment.
•
Use caution when using electrically conductive tools around the Acme Packet 1100.
•
Remove jewelry before working on the Acme Packet 1100.
Battery Warning
Note:
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERY ACCORDING TO THE INSTRUCTIONS.
Perchlorate Material — Special handling may apply. See www.dtsc.ca.gov/
hazardouswaste/perchlorate.
ESD Safety
To protect the Acme Packet 1100 delicate electronic components from damage from static
electricity, always follow the appropriate ESD procedures and wear the proper protective
devices (such as an ESD wrist strap) when handling any and all Acme Packet 1100 hardware
and while performing any Acme Packet 1100 System hardware procedures. There is an ESD
receptacle in the top left corner in the rear of the Acme Packet 1100.
Precautions
To protect your equipment from ESD, follow these ESD safety precautions:
•
Ensure that the Acme Packet 1100 is properly grounded.
•
If you are grounding your Acme Packet 1100 to an electrically conductive, grounded rack,
check to see whether or not the rack is painted. Paint can hinder proper grounding. If your
Chapter 1
Battery Warning
1-2