A
Alarms
The Acme Packet 1100 generates internal alarms that correspond to internal hardware fault
conditions. Hardware faults are divided into two types:
•
Hardware and environmental
•
Media link
Each alarm is assigned a severity level, depending on the details of the fault.
Table A-1 Descriptions of Alarm Severity Levels (cont.)
Alarm Severity
Description
Minor
Functionality is impaired to a small degree (e.g., a single fan has
failed)
Major
Pending failures or unexpected events are imminent (e.g., an LOS)
Critical
Catastrophic condition has occurred (e.g., the system is overheating)
The Acme Packet 1100 polls its hardware components to ensure they are functioning properly.
If it encounters a fault condition, it will report alarms in these categories:
•
Hardware temperature
•
Fan speed
•
Environmental sensor
•
Power supply
•
Voltage
•
Physical interface cards
Hardware and Environmental Alarms
This section provides details about hardware and environmental alarms.
Hardware Temperature Alarm
The following table lists the hardware temperature alarm.
Table A-2 Hardware Temperature Alarm Information (cont.)
Alarm Name
Alarm
ID
Alarm Severity Causes
Example Log
Message
Graphic Display
Window Message
TEMPERATU
RE HIGH
65538 CRITICAL:
>100°C
MAJOR:
>95°C
MINOR: >90°C
Fans are
obstructed or
stopped. The
room is
abnormally hot.
Temperature:
XX.XXC
(where XX.XX is
the temperature in
degrees)
Temperature X C
(where X is the
temperature in
degrees)
A-1