background image

 

 

 

Battery Charger BT-C3100    OPERATING INSTRUCTIONS 

               

 

1.

 

Intended Use 

The  product  is  intended  to  charge  and  discharge  NiCd,    NiMH  or 
3.7v Li-ion rechargeable batteries in size type of 16340, 10440, 14500, 
16340,  18500,  18650,  26650,  26500.  It  provides  four  independent 
charging  slots  for  rechargeable  batteries.  The  charger  can  also 
optimize  and  test  the  maximum  capacity  of  the  rechargeable 
batteries.  Each  charging  slot  has  its  own  display  to  show  various 
information,  such  as,  charging  current,  battery  voltage,  charged 
capacity, battery internal resistance and elapsed charging time. 
The  charging  current  can be  selected  for  200mA,  300mA,  500mA  , 
700mA, and 1000mA ( if  only bay 1 and/or  4 are used to charging 
batteries,  current  1500mA  and  2000mA    can  be  further  selected). 
Default charging current is 500mA. 
Discharging current can be selected between 200mA, 300mA, 500mA, 
700mA and 1000mA. Default discharging current is 500mA 
   
The charger can charge batteries of different type and size and with 
different capacity at the same time. It also integrates the minus delta 
voltage (-

Δ

V) for NiCd or NiMh battery charging termination, and for 

Li-ion batteries charging to 4.2V with pre-selected constant current. 
When  battery  is  fully  charged,  the  charger  will  switch  to  trickle 
charging automatically. Therefore battery will be kept at its optimum 
capacity.  The  charger  also  includes  overheat  detection  to  protect 
rechargeable  batteries  and  charger  itself  from  overheating.  When 
temperature sensor detects PCB or battery voltage is over 40 degrees 
Celsius, then the fan will be turned on automatically. Only when all 6 
temperature sensors temperature is measured less than 40 degrees 
Celsius, then the fan will be switched off.   
The charger can only be powered by power supply rated 12v/3.0A. 
Operate and store it in dry indoor environment only. 
This product fulfills European and national requirements related to 
electromagnetic compatibility (EMC). CE conformity has been verified 
and the relevant statements are available upon request. 
Unauthorized  conversion  and/or  modification  of  the  device  are 
inadmissible because of safety and approval reasons (CE). Any usage 
other  than  described  above  is  not  permitted  and  can  damage  the 
product and lead to associated risks such as short-circuit, fire, electric 
shock,  etc.  Please  read  the  operating  instructions  thoroughly  and 
keep them for future reference. 
The  charger  has  its  backlight  turned  on  after  each key  press.  Back 
light will be switched off after 30 seconds when no key is pressed. 

The maximum charging capacity can be up to 20,000mAH. 

2.

 

Delivery Content 

Battery Charger BT-C3100     

1pcs 

Power Adapter   

 

 

1pcs 

Operation Instructions  

 

1pcs 

 

3.

 

Safety Instructions

               

 

We  do  not  assume  liability  for  resulting  damages  to  property  or 
personal  injury  if  the  product  has  been  abused  in  any  way  or 
damaged  by  improper  use  or  failure  to  observe  these  operating 
instructions. The warranty will then expire! 
3.1 Product Safety 

 

The  product  must  not  be  exposed  to  substantial  mechanical 
strain or strong vibrations. 

 

The product must be protected against electromagnetic fields, 
static electrical fields, extreme temperatures, direct sunlight and 
moisture 

 

The  manufacturer’s  instruction  for  the  respective  batteries 
must be observed, before they are charged. 

 

The product should not be connected immediately after it has 
been brought from an area of cold temperature to an area of 
warm  temperature.  Condensed  water  might  destroy  the 
product.  Wait  until  the  product  adapts  to  the  new  ambient 
temperature before use. 

Sufficient ventilation is essential when operating the charger. Never 
cover the ventilating slots of the charger, especially area in front of 
the cooling fan need to be at least 8cm free open area for enough 
ventilation purpose.    Please take cautions especially when ambient 
temperature is over 35 degrees Celsius and charging current rate is 
over 0.5C. If higher charging current applied, it is more easy to build 
up temperature on batteries. 
 
3.2    Battery Safety 

 

Correct polarity must be observed while inserting the batteries. 

 

Non-rechargeable  batteries,  rechargeable  alkaline  batteries 
(RAM),  lead  acid  batteries  must  not  be  charged  with  this 
product. There is danger of explosion! 

 

Batteries should be removed from the device if it is not used for 
a long period of time to avoid damage through leaking. Leaking 
or damaged batteries might cause acid burns when in contact 
with  skin,  therefore  use  suitable  protective  gloves  to  handle 
corrupted batteries. 

 

Batteries must be kept out of reach of children. Do not leave the 
battery  lying  around,  as  there  is  risk,  that  children  or  pets 

Reviews: