6.4 SLOT Selection. 
This button is used to select desired slots for different working mode, 
charge current or display mode. Press SLOT button will start the slots 
selection  processing  in  the  sequence  cycle  of  1->2->3->4->4 
slots->exit.   
 

7.

 

Overheat Protection 

When  charger  works  at  high  current,  there  will  be  massive  heat 
generated inside the charger. To achieve a good charging result as 
well  as  keeping  batteries  at  the  top  condition,  lowest  temperature 
rise is very important for both charger and battery. BT-C3000 charger 
is  equipped  with  a  temperature  controlled  cooling  system.  When 
internal temperature is lower  than  40C,  fan  will  be stopped.  When 
internal temperature or battery temperature is over 40C, fan will be 
switched on.   
With our improved charging circuit design, for normal good quality 
battery  with  low  impedance,  heating  built  up  on  battery  during 
charging  process  is  almost  unnoticeable.  However  during  the  last 
charging stage for Ni-Cd or Ni-Mh batteries, when battery is almost 
full,  batteries  can  become  hot.  This  is  normal:  the  larger  charging 
current  applied,  the  more  heat  will  build  up.  When  battery 
temperature is sensed to be over 60C, then over heat protection will 
be  kicked  in  for  safety  reason.  When  overheating  occurs,  current 
working mode for all 4 slots will be automatically halted. To tell if it is 
in the state of overheating protection mode, charging current will be 
reduced to 0mA.   

Charging/discharging  process  will  only  resume  after  battery 
temperature drops below 40 degrees Celsius.   

     

8.

 

Operation Modes and Display 

8.1 Operation Modes: 

 

Charge Mode: The rechargeable battery is charged up to its 
maximum  capacity.  Accumulated  charging  capacity  is 
displayed  at  mAH  display  mode.  For  Ni-MH  or  Ni-Cd 
batteries, after charging mode is completed, a trickle charge 
current  (around  10mA)  will  be  applied.  For  Li-ion  battery, 
once  charge  mode  is  completed,  no  trickle  charge current 
will be applied. When Li-ion battery voltage is dropped less 
than  4.0v,  then  charging  will  be  activated  until  battery 
voltage reaches 4.20v. 

 

Discharge Mode: It is used to reduce the memory effect. The 
rechargeable  battery  is  discharged  to  a  preset  battery 
voltage (0.9v for Ni-Cd & Ni-Mh, 2.8v for Li-ion batteries). 

Once  discharge  is  finished,  total  accumulated  discharging 
capacity  is  displayed  at  mAH  display  mode,  showing  how 
much energy is discharged from the battery, which is always 
referring  to  the  accumulated  discharging  capacity.  Trickle 
charge  current  will  be  applied  after  discharge  cycle  is 
finished,  preventing  the  batteries  from  discharging  any 
further.   

 

Refresh  Mode:  The  rechargeable  battery  is  charged  and 
discharged repeatedly to optimize to its maximum capacity. 
Old  rechargeable  batteries  or  rechargeable  batteries  that 
have  not    been  used  for  a  long  period  of  time  can  be 
restored  to  their  rated  capacity.  Depends  on  the  selected 
charge current and battery impedance, it can take tens hours 
or even days time before complete. Refresh mode will make 
3  complete  discharge-charge  working  cycles  before 
complete. After charge cycle is complete, the total charged 
capacity will be displayed in mAH display mode even it is at 
discharging stage of that cycle.   

 

Test mode:    Checks the present capacity of a rechargeable 
battery. The maximum capacity is determined by discharging 
the  rechargeable  battery  after  it  was  fully  charged.  If  the 
maximum  capacity  is  much  lower  than  the  rated  capacity 
then it may reach the end of its lifetime. 

 

Quick  Test  mode:  The  charger  will  analyze  the  dynamic 
internal battery resistance by applying a load and the current 
reading  is  referred  to  the  voltage  drop  detected  on  the 
battery.  Within  10s,  the  tested  battery  resistance  will  be 
displayed in the unit of milliohm. For good quality batteries, 
the internal resistance is very low: in the range of  20 ~ 80 
milliohms. If battery internal resistance is over 500milliohms, 
then  these  batteries  are  not  good  for  supplying  power  to 
high current loads, such as digital camera etc. But they can 
still  be  used  for  low  energy  loads,  such  as  clock,  remote 
controllers  etc.    Always  use  batteries  with  close  internal 
resistance  range  when  they  are  used  in  serial  to  achieve 
maximum battery life. Alkaline and any other 1.5v batteries 
can be tested on this charger as well. If a completely empty 
battery is to be tested, it is not possible to give any correct 
reading.  Please  be  noted  that  since  the  internal  battery 
resistance can be very small, and contact resistance can be a 
major influence factor, thus same battery tested in different 
slot or even at the same slot with different contact condition, 
the  reading  can be  varied  for  10%  to  20%.  This is normal. 
Test twice if needed to assure a correct measurement result. 