background image

lead acid batteries must not be charged with this product.  There is 

danger of explosion! 

 

Batteries  should  be  removed  from  the  device  if  it  is  not  used  for  a 

long  period  of  time  to  avoid  damage  through  leaking.  Leaking  or 

damaged batteries might cause acid burns when in contact with skin, 

therefore  use  suitable  protective  gloves  to  handle  corrupted 

batteries. 

 

Batteries  must  be  kept  out  of  reach  of  children.  Do  not  leave  the 

battery lying around, as there is risk, that children or pets swallow it. 

 

Batteries must not be dismantled, short-circuited or thrown into fire. 

 

Never  recharge  non-rechargeable  batteries.  There  is  a  risk  of 

explosion! 

 

Repair  works  must  only  be  carried  out  by  a  specialist/specialist 

workshop. 

 

If  you  have  queries  about  handling  the  device,  which  are  not 

answered  in  this  operating  instruction,  please  check  with  the 

distributor for further help. 

 

4. 

Operating Elements 

         

                     

 

 

 

5. 

Power Supply 

The shipped power adapter is the power supply for this charger. In case you need to use other power adapter, please be aware that power supply has the 

correct polarity plug. Also please be noted that power supply need be able to supply minimum 3.0A current. Low output power adapter could lead to working 

improperly. After powering up, all LCD segments will light up and then showing firmware version 2.1 momentary. “null” will be shown when no battery is 

loaded inside charger.   

 

6. 

Operation 

Once a rechargeable battery is inserted, its present voltage( for example, “1.12v”) will be displayed for 3 seconds, then 500mA default charging current will 

be shown on display for another 3 seconds. If 

MODE

 or 

CURRENT 

button is not pressed during this 6 seconds, charging process will start. During the first 6 

second time, If any button is pressed, the unit will wait for another 10s before finishing current slot setting. Press “SLOT” button will confirm the setting right 

way without the needs of waiting the 10s auto time-out time elapsed. All other battery can be handled the same. So each battery can have its own setting 

independently. 

While the previous battery slot setting mode is in effective (telling by the flashing display of that battery slot LCD ), and the next battery is inserted, then both 

battery slot display will be flashing, which means that any setting change will be applied for all batteries in setting mode at the same time. 

Once start normal working mode, charging current can no longer be changed unless its working mode is changed or batteries are taken out from charger 

and insert into charger again. 

During normal working mode, if no particular slot is selected by pressing the SLOT button, MODE, CURRENT and DISPLAY button are always referring to 4 

slots simultaneously. If a different working or display mode is desired for particular slot, press the SLOT button to select the slot and then   

press “Mode” or “Display” to select your wanted working or display mode.. 

6.1 Mode Selection 

 

Press and hold the “MODE” button for 2 seconds to start working mode selection for all four battery slot.   

 

Press the “MODE” button subsequently to toggle among the “Charge”, ”Discharge”, ”Test” , “Quick Test” and “Refresh” mode 