background image

 

When particular slot working mode need to be changed, press SLOT button to select the desired slot and then press MODE button to choose wanted 

working mode. 

 

When working mode is changed, working current adjustment is possible. 

6.2 Current Selection 

Within the first 6 seconds after inserting battery or right after power up, press the “CURRENT” button to select desired charge current for slots loaded with 

battery  at  the  same  time.  Current  setting  can  not  be  altered  once  setting  has  been  confirmed  in  the  initial  stage.  If  different  working  current  is  needed 

afterwards, either changing working mode or rechargeable battery must be taken out and inserted again. Discharge current is set to the selected charge 

current selected.   

6.3 Display Selection 

“DISPLAY”  button  is  for  toggling  display  information  for  voltage,  current,  capacity,  work  time  etc.  Press  “Display”  button  for 3s,  it  will  turn on  back  light 

permanently. Press this button for another 5s to de-activate this function. 

6.4 SLOT Selection. 

This  button  is  used  to  select  desired  slots  for  different  working  mode,  charge  current  or  display  mode.  Press  SLOT  button  will  start  the  slots  selection 

processing in the sequence cycle of 1->2->3->4->4 slots->exit.   

 

7. 

Overheat Protection 

When charger works at high current, there will be massive heat generated inside the charger. To achieve a good charging result as well as keeping batteries 

at the top condition, lowest temperature rise is very important for both charger and battery. BT-C3000 charger is equipped with a temperature controlled 

cooling system. When internal temperature is lower than 40C, fan will be stopped. When internal temperature or battery temperature is over 40C, fan will be 

switched on.   

With our improved charging circuit design, for normal good quality battery with low impedance, heating built up on battery during charging process is almost 

unnoticeable. However during the last charging stage for Ni-Cd or Ni-Mh batteries, when battery is almost full, batteries can become hot. This is normal: the 

larger charging current applied, the more heat will build up. When battery temperature is sensed to be over 60C, then over heat protection will be kicked in 

for  safety  reason.  When  overheating  occurs,  current  working  mode  for  all  4  slots  will  be  automatically  halted.  To  tell  if  it  is  in  the  state  of  overheating 

protection mode, charging current will be reduced to 0mA.   

Charging/discharging process will only resume after battery temperature drops below 40 degrees Celsius.       

 

8. 

Operation Modes and Display 

8.1 Operation Modes: 

 

Charge Mode: The rechargeable battery is charged up to its maximum capacity. Accumulated charging capacity is displayed at mAH display mode. 

For Ni-MH or Ni-Cd batteries, after charging mode is completed, a trickle charge current (around 10mA) will be applied. For Li-ion battery, once 

charge mode is completed, no trickle charge current will be applied. When Li-ion battery voltage is dropped less than 4.0v, then charging will be 

activated until battery voltage reaches 4.20v. 

 

Discharge Mode: It is used to reduce the memory effect. The rechargeable battery is discharged to a preset battery voltage (0.9v for Ni-Cd & Ni-Mh, 

2.8v for Li-ion batteries). Once discharge is finished, total accumulated discharging capacity is displayed at mAH display mode, showing how much 

energy is discharged from the battery, which is always referring to the accumulated discharging capacity. Trickle charge current will be applied after 

discharge cycle is finished, preventing the batteries from discharging any further for NiMh and NiCd battery.   

 

Refresh Mode: Rechargeable battery is charged and discharged repeatedly to optimize to its maximum capacity. Old rechargeable batteries or 

those  that  have  not  been  used  for  a  long  period  of  time  can  be  restored  to  their  rated  capacity.  Depends  on  selected  charge  current,  battery 

capacity and battery impedance (healthy state), it can take tens hours or even days time before complete. Refresh mode will make 3 complete 

discharge-charge working cycles before complete. After discharge cycle is  completed, total discharged capacity  will be  kept displayed in mAH 

display state even next charging cycle is in progress.   

 

Test mode:    Checks the present capacity of a rechargeable battery. The maximum capacity is determined by discharging the rechargeable battery 

after it was fully charged. If the maximum capacity is much lower than the rated capacity then it may reach the end of its lifetime. 