Operating
37
-
values which are lower than their predecessors will only be taken over if the temperature
has fallen below the
Threshold
value beforehand. If
Hysteresis
is activated a peak in
addition must decrease by the value of the hysteresis before the algorithm takes it as a
new peak value.
AVALL
(Advanced Valley Hold): This mode is the inverted function of Advanced Peak
hold. The sensor waits for local minima. Minimum values which are higher than their
predecessors will only be taken over if the temperature has exceeded the
Threshold
value beforehand. If
Hysteresis
is activated a minima in addition must increase by the
value of the hysteresis before the algorithm takes it as a new minimum value.
U °C
Setup of the
Temperature unit
[°C or °F].
M 01
Setup of the
Multidrop address
. In a
RS485
network each sensor will need a specific
address. This menu item will only be shown if a RS485 interface board is plugged in. For
using the
RS422
mode, press once the down button on M01.
BAUD 115.2K
Setup of the
Baud rate
for digital data transfer.