optris CSmicro – E2011-08-B
12
2WhsLT
2W2M
e
Temperature range IR
-20...150 °C
385...1600 °C
(scalable via software)
Ambient temperature (sensing head)
-20...75 °C
-20...125 °C
Spectral
range
8-14
µm
1,6
µm
Optical
resolution
15:1
75:1
Accuracy
1)
±1 °C or ±1 %
3)
±(0,3 % of r 2 °C)
2)
Repeatability
1)
±0,3 °C or ±0,3 %
3)
±(0,1 % of r 1 °C)
2)
Temperature coefficient
5)
±0,05 K/ K or ±0,05 %/ K (whichever is greater)
Temperature
resolution
0,025
K
3) 4)
0,1 K
Response time
150 ms (90 % signal)
10 ms (95 % signal)
Warm-up
time
10
min
-
Emissivity/
Gain
0,100...1,100 (adjustable via software)
Transmissivity
0,100...1,000 (adjustable via software)
Interface (optional)
USB programming interface
Signal processing
Average, Peak hold, Valley hold (adjustable via software)
1)
at ambient temperature 23
5 °C; Epsilon = 1; Response time = 1 s
2)
at object temperatures > 450 °C
3)
at object temperatures > 20 °C
4)
at time constants > 0,2 s
5)
for ambient temperatures <18 °C and >28 °C
Summary of Contents for CSmicro 2W2M Series
Page 1: ...optris CSmicro LT 2WLT 2WLTH 2W2M 2WhsLT Infrared Sensor Operators manual...
Page 2: ......
Page 16: ...LT15 2WLT15 2WLT15H 2WhsLT with CF lens 0 8 mm 10 mm LT02 D S 2 1 optris CSmicro E2011 08 B 14...
Page 17: ...LT02 with CF lens 2 5 mm 23 mm 2W2M SF D S 75 1 optris CSmicro E2011 08 B 15...
Page 28: ...Air Purge Collar 2WhsLT Air purge collar for 2WhsLT head ACCTAPMH optris CSmicro E2011 08 B 26...