![Optoma GT-7000 Service Manual Download Page 41](http://html.mh-extra.com/html/optoma/gt-7000/gt-7000_service-manual_1644724041.webp)
HD65/GT-7000/HD700X
Confidential
4-0
x 100%
note: P5=center of white image
B5=center of black image.
Criteria
- 1200:1
4. Uniformity
Procedure
- Full white pattern
- Use CL100 to measure brightness values of
P1~P9 (see image: full white).
- Follow the Uniformity formula to calculate
average values.
☼ Uniformity Formula
ANSI Uniformity = Avg. (P1, P3, P7, P9)
P5
Criteria
- 65% (JBMA)
4-9 Others
1. Functional Inspection
Keypad button
- All keypad buttons must operate
smoothly.
General
- All OSD functions must be
checked for functionality. When
OSD menu is displayed, there
shall be no visible peaking,
ringing, streaking, or smearing
artifacts on the screen.
Factory Default
- The factory settings (with appro
-
priate centering, size, geometry
distortion, etc.) shall be displayed
upon “Recall” is selected from
OSD