Confidential
4-4
EX612/EX615/EW615i/EX612i/EX615i
EX615i
4-11 Optical Performance Measure
Inspection Condition
- Environment luminance: 10.0 Lux
- Product must be warmed up for 5 minutes
- Distances from the screen: 1.95 M
- Screen Size: 60 inches diagonal
1. Test equipment
Procedure
- Press
"
Power→ Left→ Left→ Menu
"
to get
into service mode 1.
- Select
"
Spoke Test
"
2. Brightness
Procedure
- Full white pattern
- Use CL100 to measure brightness values
of P1~P9.
- Follow the brightness formula to calculate
brightness values.
☼ Brightness Formula
Avg. (P1~P9)*1.1m
Criteria • 1400 ANSI lumen