6. 3D Test
Procedure - Test equipment: 1. DVD Player & HQFS format CD
or 2. PC with 3D Graphic card
- Test signal: 1280X720@120Hz (HQFS format CD)
Inspection item - 3D test
Inspection Distance - 5M
Criteria - The image should not appear noise, flicker,
shadow, shocking, abnormal color.
4-10 ADC Calibration
1. Video Calibration
Calibration
Procedure
- Test equipment: video generator
- Once Main Board is changed, video calibration
should be done as well.
(1) Test signal: 480i
(2) Test Pattern: SMPTE BAR
- Note
(1) Calibration pattern should be in full screen mode.
(2) Please refer to 4-2 Guide to get into service
mode 1 and choose "ADC calibration".
(3) Choose and get into "Video Calibration", press
"Enter" button to execute "Video Calibration".
When the message "Success" appears, it means
"Video Calibration" is OK. Choose "Menu" or
"Exit" to leave service mode 1.
Check pattern
- Test signal: 576p, 720p, 1080i
- Test pattern: Master
* After finishing Video adjustment, check Master
pattern.
Inspection item
- Color saturation
Criteria
- There should not have any lack of SMPTE BAR.
- The screen appears normal, it shouldn’t appear
any abnormal condition, such as lines and so on.
- It is unacceptable that the color appears
abnormal and flashing.
SMPTE BAR
Master
Summary of Contents for EW615i
Page 86: ...Confidential III EX612 EX615 EW615i EX612i EX615i 5 4 3 2 7 1 6 Assy TOP COVER MODULE...
Page 91: ...Confidential VIII EX612 EX615 EW615i EX612i EX615i ASSY MAIN BOARD MODULE...
Page 93: ...Confidential EX612 EX615 EW615i EX612i EX615i ASSY OPTICAL ENGINE MODULE...
Page 98: ...Confidential XV EX612 EX615 EW615i EX612i EX615i A K...