ELECTRIC CONNECTION

    Remove two pulling locks on the bottom bar first before 

any operation. this is important to prevent motor damage.

OPERATING INSTRUCTION:

Plug in power supply.

    For Switch control: Plug in Switch into switch jack. Press 

button to Up position, screen goes up. Press button to stop 

position, screen stops. Press button to down position, screen 

goes down.

        For  IR  Remote:  Direct  the  handset  to  IR    window    on 

screen housing. Press the Up/Stop/Down button on the hand 

set, screen goes Up/Stop/Down accordingly.

        For  12V  trigger:  Input  12V  trigger  signal,  screen    goes 

down. Stop this signal, screen goes up.

        Electric  lock:  Press  the  Up  &  Down  buttons  on  the  IR 

handset together, then all Up & Down buttons on the switch 

and  IR  handset  will  be  locked.  To  be  unlocked  press  Stop 

button on the IR handset again or unplug the power supply 

and plug in again.

    Keeping the screen rolled in its protective case when not 

in use. Always examine both front and back of surface before 

re-rolling into case to make certain screen is free of dust, dirt 

or other foreign matter.

      Internal wiring has been completed at the factory.No 

additional wiring is necessary.

      Note:all wiring related to the screen,may only 

be serviced by a manufacturer approved trained 

electrical  technician.Tampering  with  electrical 

wiring may void warranty and release Panoview 

of liability.

Summary of Contents for DE-GWII9106E

Page 1: ...risk of electric shock do not immerse this motor ized screen in water or other liquids To reduce the risk of electric shock do not disassemble this appliance only a qualifid service technician may service or repair motorized screen Incorrect reassemble can cause electric shock when the motorized screen is used Only use accessory attachment recommended by the manufacturer Use of non manufacturer re...

Page 2: ... connection the setting of the limit switches must be made by a trained engineer only Motorized screen with IR remote control switch control 12v trigger port Technical data Input Voltage 120VAC 60HZ Output Voltage 3A Fuse 1A IR Remote Control Distance 8m 15 Horizontal 12V Trigger Jack OD3 4xID1 3 12V Trigger Signal Voltage 7 11VAC or 8 16VDC Current 2mA IR Handset 1pc Switch control 1pc SWITCH BOX...

Page 3: ...and where other furnishings in the room permit Check that voltage and frequency marked on screen is in accordance with local power utility It is suggested only to use screen indoor under normal temperature and humidity conditions Remove two pulling locks on the bottom slat bar after the case has been installed Install screen brackets onto ceiling or wall with appropriate hardware Anchor screen ont...

Page 4: ...ted at the factory No additional wiring is necessary Note all wiring related to the screen may only be serviced by a manufacturer approved trained electrical technician Tampering with electrical wiring may void warranty and release Panoview of liability ...

Page 5: ...the Up Stop Down button on the hand set screen goes Up Stop Down accordingly For 12V trigger Input 12V trigger signal screen goes down Stop this signal screen goes up Electric lock Press the Up Down buttons on the IR handset together then all Up Down buttons on the switch and IR handset will be locked To be unlocked press Stop button on the IR handset again or unplug the power supply and plug in a...

Page 6: ... necessary to adjust for more or less please follow the steps below for adjustment Disconnect the power supply first before any operation Remove the plate on right bottom side of screen housing This is important Loosen Fasten Screw F first before adjustment Upper limit switch is on the left side and bottom limit is on the right side Tighten Fasten Screen F after all adjustment PLATE LEFT SCREW LS ...

Page 7: ...n down to test the stop position If the screen does not drop enough adjust the limit switch again Repeat until the desired position is set When complete fasten middle fasten screw F and small right fasten screw FR SETTING THE UP LIMIT POSITION CAUTION Do not allow the slat bar to become wedged between the roller and case This could damage the fabric and motor Always check that the slat is free to ...

Page 8: ...eft fasten screw FL Turn left screw LS counterclockwise to increase the amount of up travel Run the screen up to test the stop position If more travel ie desired adjust the limit switch again Repeat until the desired position is set When complete fasten middle fasten screw F and small left fasten screw FR ...

Reviews: