11
Operation
(cont.)
Serial Data Interface
The Optoelectronics Optolinx computer control interface is needed in order to download the memories of
the CD100. All cables necessary for download are included with the Optolinx.
1.
Press the FUNCTION button until INTERFACE TYPE is selected.
2.
Press the UP / DOWN ARROW button to select CI-5 COMMAND.
3.
Attach the 2.5mm portion of the CBCI5 cable to the CI-5 jack on top of the CD100. Attach
the 3.5mm portion of the cable to either jack on the Optolinx labeled A, B, or C.
4.
Load program and follow directions in the software.
Auto Power Off
The Auto Power Off function can be enabled or disabled. Enabling this function allows the CD100 to
automatically shut itself off after 2 minutes of inactivity.
1.
Press the FUNCTION button until AUTO POWER OFF is displayed. (Default: Enabled)
2.
Press the UP / DOWN ARROW button to select ENABLED or DISABLED.
3.
Press the FUNCTION button or the TEST button to exit FUNCTION mode.
Frequency Display
Press the FUNCTION button for Frequency Display then press UP / DOWN arrow to changeto:
1.
Channel: This displays the actual channel that the trasnmitter is on. EX: 454.1250
2.
Measured: This displays the actual frequency that is being trasnmitted. EX: 454.1247