background image

Summary of Contents for SNAP PAC SNAP-IT-PM Series

Page 1: ... programming human machine interface HMI development and configuration software Other models provide a modem for remote communication or offer a SNAP PAC brain instead of a controller The brain does not include programming capability but provides local intelligence for I O processing and communications With any SNAP IT model you add the analog digital and special purpose input output I O modules n...

Page 2: ...00 TEK OPTO 835 6786 951 695 3080 Hours are Monday through Friday 7 a m to 5 p m Pacific Time Fax 951 695 3017 Email support opto22 com Opto 22 website www opto22 com For this purpose Use this document Form Wire I O modules or find out module specifications SNAP Digital Input Modules Data Sheet SNAP Digital Output Modules Data Sheet SNAP Analog Input Modules Data Sheet SNAP Isolated Analog Input M...

Page 3: ...an be in one of only two states either on or off Dry contacts and door sensors are examples of digital devices Four channel modules each have four points high density digital modules have more than four points usually 16 or 32 These points are used either as inputs to report a device s on off status or as outputs to turn a device on and off remotely Analog modules monitor or control devices that h...

Page 4: ...ther module types can be in any position 1 Make sure all power to the SNAP IT unit is off Open the unit s door and remove the small white fuse from the module mounting rack WARNING Make sure there is no power tothe rack before continuing or you may severely damage the module 2 Notice that each connector position on the mounting rack has a number beginning with zero on the far left 3 Position the m...

Page 5: ...es they monitor 7 Replace the small white fuse on the module mounting rack Mounting the Unit Mount the SNAP IT PM unit securely on a convenient wall or piece of equipment Using the SNAP IT Unit on the Ethernet Network 1 Before connecting power to the SNAP IT unit read instructions in the PAC Manager User s Guide about assigning an IP address 2 Inside the unit connect external AC power to the unit ...

Page 6: ...High density digital modules do not have status LEDs LEDs for other modules LEDs are provided on some other modules usually to indicate status or diagnostic information See the module s user s guide for details Enclosure SNAP IT PM all models Standard enclosure meets NEMA 3R NEMA 3 or NEMA 4 is recom mended for exterior use Dimensions 16 19 W 18 25 H 6 57 D Communications Protocols SNMP SMTP FTP a...

Page 7: ...e release latch Pull straight out on the module the opposite direction from the rack to remove it 5 When you have finished removing and installing modules replace the small white fuse on the module mounting rack and plug power back into the SNAP IT unit Notes on Maintenance and Troubleshooting Instructions for maintenance and troubleshooting are in the PAC Manager User s Guide and in the controlle...