OptiPure 164-01502 Simple Install Manual Download Page 2

OPS70CR Simple Install Guide 

2.5 gals. Bladder Tank Shown

Completed 

OPS70CR Installation

Service Contact

For local maintenance and service information, please 

contact your nearest Authorized Service Representative. 

Service inquiries may be directed to technical support at:

OptiPure, A Division of Aquion, Inc.

101 S. Gary Ave., Suite A

Roselle, IL 60172 USA

Phone #:  972.881.9797

E-mail correspondence to: [email protected] 

Environmental Conditions

The OPS70CR is certified to operate under the following 

conditions:

1.  Altitude up to 2000 m.

2.  Ambient Temperature of 40˚ - 105˚F (5˚ - 40˚C).

3.  Maximum Relative Humidity 80% at 88˚F (31˚C).  

4.  Installation Category II.

5.  Pollution Degree II.

6.  Indoor use only, protect from elements. 

Safety Instructions

1.  Please read and follow these instructions when 

connecting and using the system.

2.  Securely bolt processor to wall before operating.  

3.  Avoid cross-connections and install on cold water 

     supply only.  

4.  Use approved air gaps when connecting to drain lines.

5.  Do not exceed system pressure rating and use water 

hammer arrestors when water hammer is evident.

6.  Turn off feedwater supply before filter or membrane 

cartridge replacement.

v

 General Information 

Summary of Contents for 164-01502

Page 1: ...Guide Rev 1 1 OPS70_Simple_Install_v1 1 indd 2018 Procam Controls Inc All Rights Reserved Access manuals spec sheets and additional educational materials for foodservice water treatment at our website...

Page 2: ...lowing conditions 1 Altitude up to 2000 m 2 Ambient Temperature of 40 105 F 5 40 C 3 Maximum Relative Humidity 80 at 88 F 31 C 4 Installation Category II 5 Pollution Degree II 6 Indoor use only protec...

Page 3: ...A drain should be located within 10 feet of the system Drain must allow a minimum flow of 2 gals min Compliance with most local plumbing codes requires installation of an approved air gap in the drai...

Page 4: ...ater pressure and flow Cut tubing to an efficient length using a tubing cutter or sharp blade Do not cut with wire crimpers or dikes When routing and securing tubing avoid loops or kinks Membrane Reje...

Page 5: ...k and Bypass Assembly 3 8 red as shown below Step 1 Attach the system with 2 screws user supplied through the attachment keyholes shown below Use anchors or attach directly to studs Be sure to allow a...

Page 6: ...the lower left part of the Permeate Pump Attention Warranty will be void if this step is not performed properly Step 3 Insert and lock the CTO Q10 Pre Filter and CTO Q10CR Cartridge into the filter he...

Page 7: ...Gap available part number 164 89905 Step 5a Install the Feedwater Adapter from the installation kit into the user supplied 1 2 Feedwater Supply Valve Do not over tighten Step 5b Connect a piece of 3 8...

Page 8: ...The remaining connection at the Tank Tee is the Optimized Water Outlet Insert the barbed end of the connector fitting into the 1 2 gray hose and secure with clamp Insert into the Tank Tee as shown Thi...

Page 9: ...nsure Tank Valve is CLOSED Step 10 Open the Feed Valve Allow water to flow to drain until all air is purged from the system Close the Feed Valve after flushing Note During normal operation the water f...

Page 10: ...ment If used insert the barbed end of the 3 4 GHT connector supplied into the 1 2 gray hose and secure clamp Connect ONLY to the treated steam water connection at the equipment Do not connect to the d...

Page 11: ...er supply to downstream equipment is immediately needed the storage tank can be quickly filled Step 13 Simply OPEN the Bypass Valve and un filtered water will flow directly into the storage tank When...

Page 12: ...ipment When finished using equipment return the Valve to the CLOSED position DO NOT leave the system in bypass mode for prolonged periods of time IMPORTANT Leaving the system in bypass could cause dam...

Reviews: