Page 34
Original operating instructions
MF2 Vario
GB
The scale has a precision of 0.2 mm. The zero point can be adjusted using the knurled nut.
Make sure to tighten it again in the required position.
Img.4-9: Moving the cross table to the Y-direction
4.8
Inclining the spindle head up or down
INFORMATION
Use a 17/19 polygonal spanner for the clamping screws and movement screws. One is
included among the accessories.
The spindle head can be inclined forward and back 45°.
Proceed as follows:
Loosen the clamping screws (3 units) located on the spindle head-holder.
Position the spindle head in the required position by screwing in or out the movement
screw.
You must re-tighten the clamping screws.
Img.4-10: Inclining the spindle head up or down
Clamping lever
Hand wheel
Movement screw
Scale ± 45°
Clamping screws