Img.2-5:
Definition of counting direction
Distance measurements between sensor and magnetic tape and angular tolerances, must
be maintained over the entire test section! (
The max. gap without cover strip is 0.2 mm + 0.1 / -0mm. When using cover strip, the gap is
reduced by the thickness of cover strip including its cover strip. The sensor must not touch the
magnetic strip.
Img.2-6:
Distance sensor / magnetic strip
Img.2-7:
Max. deviation
Img.2-8:
Installation of sensor
2.6.4 Necessary measures:
The sensor should be positioned well away from cables with interference; if necessary a
protective screen or metal housing must be provided. The running of wiring parallel to the
mains supply should be avoided.
Contactor coils must be wired with spark suppression.
2.6.5 Maintenance
We recommend cleaning the magnetic strip's surface from time to time with a soft rag. This
avoids dirt(dust, chips, humidity ... ) sticking to the strip.
Cable outlet
Travel direction
Sensor
Counting direc-
tion negative
active side
0,
2 +
0
,1
/
- 0mm
< 1
°
< 3°
< 3°