background image

Version 1.0.1 - 2020-04-09

6

Montageanleitung

GU 5 | GU 5-H

EN

GU5_G

U5-H_G

B_1.

fm

The extraction with blower and cyclone separator has been designed and built for the extraction
of air pollutant substances on manually operated machines for tools with geometrically non-
determined blade.

It is forbidden to use the extraction unit when machining with non-water-soluble or water-
soluble cooling lubricants. The device is not suitable for the extraction of mixtures of combus-
tible dusts with fluids.

The extraction unit must only be installed and operated in a dry and well-ventilated areas.

The defined conditions of use and performance data must not be changed.

The extraction unit must neither be renovated nor modified in any other way.

Dust category L

(Low risk according to the definition of standard EN 60335-2-69). According to the EN standard,
the extraction unit is approved for dust category L and thus, for the extraction of dry, non-
combustible and dust hazardous to health with occupational exposure limit values (German
AGW) of > 1mg/m³. The clean air is emitted back to the location.

Dust category M

(Medium risk according to the definition of standard EN 60335-2-69). The extraction unit is
suitable for the extraction of dry, non-flammable dust hazardous to health where the occupatio-
nal exposure limit value is higher than 0.1 mg/m³.

Dust category H

(High risk according to the definition of standard EN 60335-2-69). The extraction unit is suitable
for the extraction of dry, non-flammable dust hazardous to health for all occupational exposure
limit values as well as for non-flammable dust with carcinogenic substances. The clean air is
emitted back to the location.

Use in dust areas with potentially explosive atmosphere (Type 22)

Safety-related, extraction units with the supplement "Type 22“ are suitable for extracting
flammable, dry non-electrically conductive dusts in Zone 22. Exceptions are dusts with ext-
remely low minimum ignition energy (MIE < 1mJ). Use with these dusts requires a case-related
safety assessment and, where applicable. further measures.

Safety-related, the extraction unit is not suitable for extracting potentially explosive substances
in line with §1 Explosives Act. Do not extract hot gases, ignition sources of any type, sparks
generated mechanically or electrostatically charged materials. 

If the extraction unit is used other than as specified above, without the permission of the
company Optimum Maschinen Germany GmbH, the machine is no longer used properly. 

We will not be held liable for any damages resulting from any operation which is not in
accordance with the intended use.

We expressly point out that the guarantee will expire, if any constructive, technical or procedu-
ral changes are not performed by the company Optimum Maschinen Germany GmbH. It is also
part of the intended use that you

observe the limits of the extraction unit,

the assembly instruction is observed, 

the inspection and maintenance instructions are observed.



 Technical specification on page 9

CAUTION!

Extremely severe injuries due to non-intended use.

Conversions and modifications of the operating values of the extraction uit are
forbidden. They could pose an accident hazard to persons and cause damage to the
extraction unit.

Summary of Contents for 3107114

Page 1: ...EN Operating Manual Extraction unit Version 1 0 1 Item no 3107124 GU 5 H GU 5 Item no 3107114 GU 5 GU 5 H...

Page 2: ...Unpacking 11 3 4 Commissioning 11 4 Operation 4 1 Extraction unit function description 12 4 2 Functional Description of the Electrical Connections 12 4 3 General information 12 4 4 Fire and Explosion...

Page 3: ...nce all maintenance works and functional tests are described which the operator must perform in regular intervals The illustration and information included in the present manual can possibly deviate f...

Page 4: ...icable regulations of each country must be observed If necessary relevant measures must be taken to comply with national regulations before commissioning the extraction unit Always keep this documenta...

Page 5: ...s INFORMATION Practical tips and other important or useful information and notes No dangerous or harmful consequences for people or objects In case of specific dangers we replace the pictogram with or...

Page 6: ...for all occupational exposure limit values as well as for non flammable dust with carcinogenic substances The clean air is emitted back to the location Use in dust areas with potentially explosive atm...

Page 7: ...ility that potentially toxic highly toxic carcinogenic mutagenic or reprotoxic substances are released further protective measures are necessary according to 10 of the German Ordinance on Hazardous Su...

Page 8: ...ioning if the manufacturer or installer has confirmed to the operator that the electrical system and operating materials have been procured in accordance with the stipulations of the accident preventi...

Page 9: ...more the noise emission also depends on production engineering factors e g speed material and clamping conditions INFORMATION The mentioned numerical value is the emission level Electrical connection...

Page 10: ...damping behaviour other noise sources e g the number of machines other processes taking place in proximity and the period of time during which the operator is exposed to the noise Furthermore it is po...

Page 11: ...y occur if parts of the machine tumble or fall down from the forklift truck or from the transport vehicle Follow the instructions and information on the transport box 3 3 Unpacking Install the extract...

Page 12: ...er fans switch off as soon as machine or device connected to the 400 V socket is switched off INFORMATION The blower fans switch on only when the possible extension cable used or the 400 V socket have...

Page 13: ...air loose clothing fingers and other body parts away from the openings and moving parts of the device Do not use the device if the power cable or connector are damaged The power cable must be checked...

Page 14: ...nce redu ces after empirical values on the part of the opera tor Exhaust air Cleaning Replacing Wash the exhaust air filter with water dry and reinsert If necessary replace the exhaust air filter afte...

Page 15: ...we are not able to perform any services Defects resulting from the following circumstances are excluded from liability and warranty claims Use of the product beyond the technological capability and i...

Page 16: ...as household waste According to the European directive 2011 65 EG regarding disused electrical and electronic devices and the implementation in national law disused electrical tools and electrical equ...

Page 17: ...s on the type plate 8 2 Elektrische Ersatzteile Electrical spare parts 8 2 1 Schaltplan Wiring diagram Der aktuelle Schaltplan mit Ersatzteilliste befindet sich im Schaltschrank der Maschine oder befi...

Page 18: ...05 6 Dichtung Seal 1 0310711406 7 Beh lter Vessel 1 0310711407 8 Knopf Knob 1 0310711408 9 Verschlussschraube Locking screw 4 0310711409 10 Filter Filter 1 0310711410 11 Abdeckung Cover 1 0310711411 1...

Page 19: ...diagram power distribution Anschl sse Connections A Anschluss Schleifmaschine Grinding machine connection CEE 400V 16A B 230V Schutzkontaktsteckdose 230 V socket with earthing contact C Versorgungsan...

Page 20: ...substances in electrical and elect ronic equipment 2015 863 EU The following harmonized standards were applied EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirement...

Page 21: ...5 GU 5 H EN GU5_GU5 H_GBSIX fm Index C Copyright 15 E Electrical connection 9 I Inspection deadlines 8 L Liability claims for defects 15 M Malfunctions 14 S Safety instructions 4 T Technical specifica...

Page 22: ...Version 1 0 1 2020 04 09 22 Translation of original instruction GU 5 GU 5 H EN GU5_GU5 H_GBSIX fm...

Reviews: