Art.13  Dlsg 25 july 2005 N°151. “According to directives 2002/95/EC, 2002/96/EC and 2003/108/EC relating 
to the reduction in the use of hazardous substances in electrical and electronic equipment and waste dispo

-

sal.”

The basket symbol on equipment or on its box indicates that the product at the end of its useful life should be 
collected separately from other waste.
The  separate  collection  of  this  equipment  at  the  end  of  its  lifetime  is  organized  and  managed  by 
the  producer.  The  user  will  have  to  contact  the  manufacturer  and  follow  the  rules  that  he  adop

-

ted  for  end-of-life  equipment  collection.  The  collection  of  the  equipment  for  recycling,  treatment 
and  environmentally  compatible  disposal,  helps  to  prevent  possible  adverse  effects  on  the  environ

-

ment  and  health  and  promotes  reuse  and/or  recycling  of  materials  of  the  equipment.  Improper  dispo

-

sal  of  the  product  involves  the  application  of  administrative  penalties  as  provided  by  the  laws  in  force.

 

7.0 RECOVERY AND RECYCLING

Summary of Contents for B-500POL

Page 1: ...OPTIKA MICROSCOPES ITALY www optikamicroscopes com info optikamicroscopes com Ver 1 0 0 B 500POL OPERATION MANUAL...

Page 2: ...X 1 0 DESCRIPTION page 4 2 0 INTRODUCTION page 6 3 0 UNPACKING AND ASSEMBLY page 6 4 0 USING THE MICROSCOPE page 8 5 0 MAINTENANCE page 12 6 0 TECHNICAL SPECIFICATIONS page 13 7 0 RECOVERY AND RECYCLI...

Page 3: ...industry standards for safety instrumentation laboratory Misuse can cause personal injury or damage to the instrument Keep this manual at hand close to the instrument for an easy consultation Electri...

Page 4: ...PHOTO PORT LEVER EYEPIECE FILTER PLATE HOLDER FIELD DIAPHRAGM STAGE LOCK KNOB FILTERS OBSERVATION HEAD NOSEPIECE STAGE APERTURE DIAPHRAGM OBJECTIVE TENSION ADJUSTMENT KNOB COARSE FOCUSING KNOB FINE F...

Page 5: ...Page 5 1 0 DESCRIPTION ANALYZER INSERTION LEVER DIOPTRIC ADJUSTMENT RING BERTRAND LENS DISC CONDENSER CENTERING KNOBS BRIGHTNESS ADJUSTMENT KNOB CONDENSER ADJUSTMENT KNOB FOCUS STOP KNOB...

Page 6: ...ION 3 1 The microscope is housed in a moulded Styrofoam container Remove the tape from the edge of the container and lift the top half of the container Take some care to avoid that the optical items o...

Page 7: ...If you have a trinocular microscope and want to use the photo port insert your adaptor in the hole on the top of the observation head and fixate it with the screw on the side 3 5 Insert the eyepieces...

Page 8: ...nd lens disc under the observation head Swing out lens of the condeser in OUT position you have always to do this when observing through 4X and 10X objective 3 0 UNPACKING AND ASSEMBLY 4 0 USING THE M...

Page 9: ...diaphragm a bright spot of light Act on the condenser centering screws until you move the bright spot in the center of the image field Then re open the field diaphragm 4 8 Center the stage With the Be...

Page 10: ...n order to have a conoscopic view of your sample you can insert a Bertrand lens in the optical path by rotating the disc under the observation head The Bertrand lens can be fine aligned along Z axis b...

Page 11: ...rt or remove the lower polarizer as required It can also be rotated at any angle The analyzer filter can be inserted by means of its lever under the observation head By holding this lever it can laso...

Page 12: ...to clean the optics after use Only if needed use a cloth moistened with water and a mild detergent rinsing with water and drying immediately with a lint free cloth After use cover the microscope with...

Page 13: ...d inclined 30 and rotatable 360 Diopter adjustment on left eyepiece sleeve Interpupillary adjustment 55 75 mm EYEPIECES Wide field eyepieces WF10X 22 with field number 22 One eyepiece has a built in c...

Page 14: ...on of this equipment at the end of its lifetime is organized and managed by the producer The user will have to contact the manufacturer and follow the rules that he adop ted for end of life equipment...