16
2) Select an input port by pressing input 5 or 6 key button.
3) Press input 3 or 4 key button to change EDID mode.
3-1) If you select
Default Mode
, default EDID will be restored for allocated inputs.
===EDID Configure===
Input: 01 Default
Default Mode?
1: Y 2: N 3: << 4: >> 5:
∨ 6: ∧
Press input 1 key button then, the OMM-1000 will recover the Default EDID to
allocated input as below.
===EDID Configure===
EDID Copying
….
EDID
Reading….
3-2) If you select
Auto Mix Mode
, mixed EDID of all attached displays will be saved in
allocated input.
3-3) If you select
Output Copy Mode
, OMM-1000 reads EDID from any target displays
and copies it in allocated input.
[Note] There is Edit Data Mode but it is used to modify existing EDID to make new
EDID working with specific systems. It is not recommended for general user. For
further information, please contact [email protected]
3.3.10 Baud Rate: Press FUNCTION key button ten times
▪
It sets RS-232 Baud Rate. OMM-1000 supports 9600, 19200, 38400, 57600, 115200bps.
=====Baud rate=====
Old baud: 115200
New baud: 115200
▪
Input 3 key button decreases the number.
▪
Input 4 key button increases the number.
▪
Press ENTER key button to complete the process.
▪
The default setting is 115200