Installation
Important: Please keep the installation procedure below. Improper or no
operation may result if the start-up sequence is not correctly followed.
Step 1
Carefully unpack the contents of the shipping group.
Step 2
Plug and fasten the 5V power adapters to the
+5V DC
jack on the rear side of
converter. Ensure the Power LED ON (Blue).
Step 3
Please, check if the maximum resolution of the display is WUXGA
(1920x1200). Otherwise, follow the instructions for
Self-EDID Programming
Procedure
on page 1-5.
Step 4
Connect the VGA source to
VGA IN
port over VGA cable. If the VGA source
is active, status LED (Blue) will be turned on.
Step 5
Connect the
OPTICAL OUT
to 1-fibe DVI receiver, DVFX-100-R over multi-
mode SC-SC optical fiber.
Step 6
Plug DVFX-100-R to DVI input port of display.
Step 7
If you need on-site monitoring, connect VGA OUT on the front side to VGA
input port of local monitor over VGA cable.
1-3 Installation
Note1:
The maximum extension length by multi-mode fiber is 500 meters.
Note2:
Be recommended NOT to use any intermediate cable or adapter in
between to avoid undesirable performance degradation.
Figure 1
– Connection Diagram of VGDF-200
1-4 Installation
VGA Source
Local
VGA Display
One
(1) Op
tical
Fiber
25-0215
DVFX-100
Rx
Remote
DVI Display
Up t
o WU
XGA
25-0584
VGDF-200