Opticon
OPR 3001
Specifications Manual
9
6. Optical
Specifications
6.1. Laser Scanning Specification
Parameter Specification Unit
Light-emitting Element
Red laser diode
-
Emission Wavelength
650 ±10 (25° C)
nm
Light Output
1.0 or less
mW
Scanning Method
Bi-directional scanning
-
Scanning Speed
100 ±20
scans/s
Scan angle: 54 ±5
°
Scan Angle
Effective scan angle: 44 (Min)
°
6.2. Laser Scanning Standard
6.2.1.
Laser Scanning Tilt
Laser scanning tilt is the vertical difference between both ends of a laser scan
line. Measure it in the middle of the laser scan line.
•
Up to 1.2 degrees angle in vertical direction from the scan origin (mirror
motor).
•
Up to 3.1 mm at 150 mm from the scan origin.
6.2.2.
Scanning Curvature
The maximum difference between the laser scan line and the line between both
ends of the laser scan line. Measure it in the middle of the laser scan line.
•
Up to 1.27 degrees angle in vertical direction from the scan origin (mirror
motor).
•
Up to 3.3 mm at 150 mm from the scan origin.
Figure 2: Laser scanning tilt and curvature