8-19-19 Code128/EAN128/UPC/EAN/JAN/Code93 Verification Method (0x4D)
This parameter offers 4 levels of decode security for Code128, EAN128, UPC, EAN, JAN or
Code93 bar codes. Select security levels for decreasing levels of bar code quality.
As the security levels increase, the scanner’s aggressiveness decreases. Select the security level
suitable for the bar code quality.
Security Level 0
There will be no consistency verification before transmission.
*
Level 0 (0x0)
Security Level 1
Those types of bar codes must be successfully read twice before transmission.
Level 1 (0x01)
Security Level 2
Those types of bar codes must be successfully read three times before transmission.
Level 2 (0x02)
Security Level 3
Those types of bar codes must be successfully read four times before transmission.
Level 3 (0x03)