OPTICON
Software Guide
MDL-1000/2000
25
4-2-3.
BEEP
Function: Turn on the Buzzer
Length
Operation Code
Message Source Status Beep
Code
Checksum
05 E6 04
Field Format
Size
(Byte)
Function
Length
Length
1
The length of a packet excluding checksum.
Operation
Code
E6 1
Packet
ID
Message
Source
4:Host
1
From The Host System to This Scan Engine
Status Bit0:
Bit1: Unused
Beep Code
Beep Type ID
Checksum
2
Two’s complement sum of message contents
(from Length to Data Field).
Sound a buzzer.
Length, frequency, patterns, number of times of buzzer are as follows:
Beep
Code
Length Frequency
No. of
Time
Beep
Code
Length Frequency
No. of
Time
00
Short High 1 OD
Long
High 4
01
Short
High 2 0E
Long
High 5
02 Short
High 3 0F Long Low 1
03 Short
High 4 10 Long Low 2
04 Short
High 5 11 Long Low 3
05
Short
Low 1 12
Long
Low 4
06
Short
Low 2 13
Long
Low 5
07 Short Low 3 14 Fast
Repeat
Hi-Lo-Hi-Lo
4
08 Short
Low 4 15 Slow
Repeat
Hi-Lo-Hi-Lo
4
09 Short Low 5 16 Mix
1 Hi-Lo 2
0A Long High 1 17 Mix
2 Lo-Hi 2
0B Long High 2 18 Mix
3
Hi-Lo-Hi 3
0C Long High 3 19 Mix
4
Lo-Hi-Lo 3