background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

OPERATOR MANUAL 

 
 
 
 
 

OSD2010 

FIBER MODE  

CONVERTER 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

Summary of Contents for OSD2010

Page 1: ...OPERATOR MANUAL OSD2010 FIBER MODE CONVERTER...

Page 2: ......

Page 3: ...DICATORS 10 2 3 4 FITTING SFP CONNECTORS 11 3 MAINTENANCE 12 3 1 INTRODUCTION 12 3 2 EXTERNAL INSPECTION 12 3 3 ROUTINE MAINTENANCE 12 4 WARRANTY 13 4 1 WARRANTY PERIOD 13 4 2 REPAIRS 13 4 2 1 WARRANT...

Page 4: ...r Adding CWDM to an existing fiber network Extending optical transmission distances by operating as an optical repeater Networks using Ethernet devices such as cameras intercoms access control telepho...

Page 5: ...Please consult OSD SFP datasheets or contact OSD Alarms SFP 1 Laser Fail SFP 1 Loss of Received Optical Signal SFP 2 Laser Fail SFP 2 Loss of Received Optical Signal Alarm Interface 4 Open drain outpu...

Page 6: ...se radio interference in which case the user may be required to take adequate measures OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 2014 standard Class 1 The...

Page 7: ...PAGE 7 2 2 2 OSD2010 DRAWINGS AND DIMENSIONS The OSD2010 is designed to be mounted on an even surface and to be secured by means of M4 or smaller screws FIGURE 2 OSD2010 MOUNTING DIMENSIONS R2 1 R2 1...

Page 8: ...cated at the back of the case DC power should be connected as indicated in Table 2 TABLE 2 DC OR AC POWER CONNECTION Power Pin Specification Pin 1 10V to 36VDC or 22V to 28VAC Pin 2 0V Pin 3 10V to 36...

Page 9: ...1 0V Ground Pin 2 Laser Ch A Fail Ch A Short to GND Pin 1 when OK Ch A Open Circuit when not OK or Power off Pin 3 Rx Ch A Fail Ch A Short to GND Pin 1 when OK Ch A Open Circuit when not OK or Power...

Page 10: ...E 4 INDICATOR FUNCTION LED Specification Parameter Ch A Receive Signal OK Red No Received Signal Green Received Signal OK Ch A Laser OK Red Transmit Laser Fail Green Transmit Laser OK Ch B Receive Sig...

Page 11: ...nstalling Ensure that the SFP is fully engaged and latched into position Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP unti...

Page 12: ...and may be damaged by failure of any portion of their support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when...

Page 13: ...ative for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves t...

Page 14: ......

Page 15: ......

Page 16: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Reviews: