40
16-2. Fault Reference Codes
When a fault occurs, the icon
will flash as a reminder. See below for fault codes
for reference.
Code
Fault Event
Possible cause
Solution
01
Bus voltage over
Surge
1. Restart the inverter.
2. If the error message still
remains, please contact your
installer.
02
BUS voltage under PV or battery
disconnect
suddenly
1. Restart the inverter
2. If the error message still
remains, please contact your
installer.
03
BUS soft start
time out
Internal
components
failed.
Please contact your installer.
04
INV soft start time
out
Internal
components
failed.
Please contact your installer.
06
R SCR Close Fault
Internal
components
failed.
Please contact your installer.
07
S SCR Close Fault
08
T SCR Close Fault
09
Solar Power abnor
Solar input
voltage is too
high
1. Please check if solar input
voltage is higher than 950V.
2. Please contact your installer.
11
Solar IP Curr over
Surge
1. Restart the inverter.
2. If the error message still
remains, please contact your
installer.
17
Mcu&Dsp com
loss
Firmware
version not
compatible
please contact your installer.
18
Mcu&Dsp ver
error
22
Bat volt over
Battery voltage
exceeds the
limit.
1. Check the battery voltage.
2. If the error message still
remains, please contact your
installer.
23
Over load
The inverter is
loaded with
more than
110% load and
time is up
Reduced the connected load by
switching off some equipment.