SECTION A:
Standard: It will list local grid standard. It’s requested to have factory password to
make any modifications. Please check local dealer only when this standard change
is requested.
CAUTION:
Wrong setting could cause the unit damage or not working.
Nominal Output Voltage: 230V.
Nominal Output Frequency: 50HZ.
SECTION B:
This section contents may be different based on different selected types of
operations.
Allow AC charging duration: It’s a period time to allow AC (grid) to charge battery.
When the duration is set up as 0:00-00:00, it means no time limitation for AC to
charge battery.
AC output ON/Off Timer: Set up on/off time for AC output of inverter. If setting it
as 00:00/00:00, this function is disabled.
Allow to charge battery: This option is automatically determined by setting in
“Charging source”. It’s not allowed to modify here. When “NONE” is selected in
charging source section, this option becomes unchecked as grey text.
Allow AC to charge battery: This option is automatically determined by setting
in ”Charging source”. It’s not allowed to modify here. When “Grid and PV” or “Grid
or PV” is selected in charging source section, this option is default selected. Under
Grid-tie mode, this option is invalid.