Optex VX-402 Instalation Instructions Download Page 10

7-1-1.Detection Area Extension Function  

(DIP switch A-3/Directional Detection:OFF)

When the Directional Detection mode is selected OFF:

The functions of the VX-402 series can be extended by connecting components such as outdoor

PIR's, active IR beams or magnetic contacts to the AUX INPUT terminal.

7.FUNCTIONS

From POWER SUPPLY

(9.5-18VDC)

Case A

=>

ALARM

Case B

=>

ALARM

case:A

VX-402 series

When a slave is connected,
Please remove the jumper.

AUX INPUT

POWER INPUT

ALARM OUTPUT

  (NC.)

To Control Panel

ALARM

OTUPUT

VX-402  Series

POWER

INPUT

Slave

(additional sensor)

case:B

Slave

Alarm signal will be sent to the control panel when either VX-402 series
or slave activates.
(In VX-402REC, do not set the voice mode switch as Pre-Warning.)

SLAVE -> VX-402 series :

VX-402 series -> SLAVE :

When the Directional Detection mode is selected ON:

7-1-2.Directional Detection Function 

(DIP switch A-3/Directional Detection:ON)

When a person passes the SLAVE area then
enters the area covered by the VX-402 series
w i t h i n   1   m i n u t e ,   t h e   V X - 4 0 2   s e r i e s   w i l l
activate.(See page 11.)

When a person passes the VX-402 series area
then enters the area covered by the SLAVE
unit within 1 minute, the VX-402 series will
activate. (See page 11.)

-10-

Alarm signal will be sent to the control panel when both VX-402
series and slave activate. In this case, select the direction by the
DIP switch A. (See section 6-6 on page 9.)

In VX-402REC, set the voice mode
switch as Pre-Warning.

7-1.Two Detectors Mode

Wiring Diagram

Voice Mode Switch

1234

alarm shop

Summary of Contents for VX-402

Page 1: ...d to avoid detecting unwanted objects By limiting the detection range false alarms due to unwanted movement i e cars persons or animals outside the protected area can be reduced VX 402 is designed to...

Page 2: ...ury or even death if the warning given is ignored Warning This icon indicates actions to be avoided Details of the actions to be avoided are written beside or near icon This icon indicates instruction...

Page 3: ...Do not touch Speaker VX 402REC only Plate Lock Screw Lock Screw Cover LED Indicator DIP Switch A Page 9 Lens Holder Lens Cover Area Masking Plate Page 8 DIP Switch B Page 9 Detection Length Adjustmen...

Page 4: ...base through the wiring hole at the terminals Apply an adhesive sponge pad over the wiring hole Hook the unit base onto the plate Adjust the DIP switch detection area and sensitivity Secure the cover...

Page 5: ...irectly into the bottom of the unit by removing the knockout on the bottom on the cover Knockout 4 WIRING VX 402REC AUX INPUT NC VX 402 AUX INPUT NC Power wires should not exceed the following lengths...

Page 6: ...recording is completed the detector automatically plays back the recorded message sound Listen to check if the sound volume and quality are satisfactory If not go back to step 3 above and repeat the p...

Page 7: ...mal conditions IMPORTANT If there is a traffic near the dettection area please adjust detectiion 1 5m to 2 0m 5ft to 7ft away from movements See section 8 OPERATION TEST on page 13 for the details Sid...

Page 8: ...ens on the zone to be eliminated IMPORTANT As shown at left the active detection fingers are always 7 if the area masking plate is not applied The active fingers are varied by area adjustment as expla...

Page 9: ...ee section 6 6 4 External speaker An external speaker may be connected to the VX 402REC detector to thunder the intruder away DIP SWITCH A NIGHT ONLY DAY NIGHT DETECTABLE DIRECTION ALARM OUTPUT DIRECT...

Page 10: ...ve activates In VX 402REC do not set the voice mode switch as Pre Warning SLAVE VX 402 series VX 402 series SLAVE When the Directional Detection mode is selected ON 7 1 2 Directional Detection Functio...

Page 11: ...When it passes along the area of slave Caution Message A Caution Message A When it passes along the area of VX 402REC When it passes along the area of slave No Voice VX 402REC VX 402 402REC VX 402REC...

Page 12: ...different messages when it is set for the armed mode or disarmed mode Armed Message A Disarmed Message B Caution Message A Warning Message B Caution Message A Warning Message B ARMED Control Panel DI...

Page 13: ...e around 8m 27ft which is rather shorter than ideal length but can remove the chance of false detection a b IMPORTANT When the car or person goes near the detection area a please adjust the detection...

Page 14: ...2 on page 7 8 Lower detection area receives reflected sunlight or car light etc Remove the reflector or reset the detection area or mask the area exposed to reflected light See section6 1 3 on page 7...

Page 15: ...and make sure that the indicator blinks during recording See section 5 2 on page 6 Connection cable is not suitable for monaural recording Cable is not connected to the earphone or headphone jack Rec...

Page 16: ...Zones 14zones Mounting Height 0 8 1 2m 2 7 4ft Sensitivity 2 0 C 3 6 F at 0 6m s Detectable Speed 0 3 1 5m s 1 5ft s Power Input 9 5 18VDC Current Draw NC Normal 25mA Max 28mA Normal 25mA Max 180mA NO...