OPTEX CO., LTD.
Manufacturer
5-8-12 Ogoto Otsu 520-0101, Japan
TEL.: +81(0)77 579 8700 FAX.: +81(0)77 579 7030
WEBSITE: ww
w
.optex.net
OPTEX Technologies B.V.
European Subsidiary
Henricuskade 17, 2497 NB The Hague, The Netherlands
TEL.: +31(0)70 419 41 00 FAX.: +31(0)70 317 73 21
E-MAIL: [email protected] WEBSITE: ww
w
.optex.eu
East coast office
8510 McAlpines Park Drive, Suite 108
Charlotte, NC 28211 U.S.A.
TEL.: +1-800-877-6656 FAX.: +1(704)365-0818
WEBSITE: ww
w.ot-inc.com
OPTEX INCORPORATED
North and South America Subsidiary
18730 S. Wilmington
Avenue, Suite 100 Rancho
Dominguez CA 90220 U.S.A
TEL.: +1-800-877-6656 FAX.: +1(310)898-1098
WEBSITE: ww
w.ot-inc.com
Area settings
Click [Admin] on the login screen
and enter the password
(default setting: admin). After
entering the password, click
[Login].
Set the following each item and press the application button below.
Click [Area] from the upper menu.
Activation output timing
Adjust the Activation output timing fitting for the installation environment. Specifying a "Fast" value
speeds up the Activation output timing, ensuring safety for rushing in, while energy-saving
efficiency gets worse as Activation output is made earlier for a slow approach. Specifying a "Slow"
value speeds down the Activation output timing, ensuring higher energy-saving efficiency, while
safety for a quick approach such as rushing in gets worse.
*As for other setting items and the detailed setting method, confirm the explanation on the web screen.
*When the cursor is moved over to
on the Web screen, the explanation is shown.
* Windows is a registered trademarks of Microsoft Corporation in the United States and/or other countries.
STEP 1
STEP 3
STEP 2
- (2) -
Password settings
User Password Settings
You can change the password for user login.
Administrator password settings
The administrator password can be changed. Make sure to change the
password from the default setting by installer from the information security
point of view. Without the initial change, there is a possibility that unspecified
users may be able to change the settings and it may result in serious
accidents. Make sure to keep the password somewhere safe.
Door position
Drag and drop the and the marks
on the camera image to specify the
door opening width.
Installation height
Set the height of the sensor installation
suited to the installation environment.
Sensitivity
Adjust the detection sensitivity fitting
for the installation environment.
Normally, set to [Standard].
Human body detection size
Adjust the human body detection size
suited to the installation environment.
Normally, set to [Standard].
Adjust the human recognition area
suited to the installation environment.
In normal case, specify the setting so
that the area should cover the entire
camera image. On the image, the
yellow line is displayed.
Human recognition area
eTracker area
Drag and drop the and the marks
on the camera image to specify the
detection area range configured (or to
be configured) for the existing
automatic door sensor.
* eTracker is a unique indicator that
shows the contribution rate to the
environment compared with the
conventional automatic door sensor,
and it can numerically indicate the
effect of the installation of this device.
To view eTracker, install the
application dedicated to smart devices,
"VVS eTracker", on your device.
Unnecessary openings due to
following conditions may be reduced
by selecting an object(s). In normal
cases it can be disabled.
Immunity