Area settings

Click [Admin] on the login screen

and enter the password

(default setting: admin). After

entering the password, click

[Login].

Set the following each item and press the application button below.

Click [Area] from the upper menu.

Activation output timing

Adjust the Activation output timing fitting for the installation environment. Specifying a "Fast" value

speeds up the Activation output timing, ensuring safety for rushing in, while energy-saving

efficiency gets worse as Activation output is made earlier for a slow approach. Specifying a "Slow"

value speeds down the Activation output timing, ensuring higher energy-saving efficiency, while

safety for a quick approach such as rushing in gets worse.

*As for other setting items and the detailed setting method, confirm the explanation on the web screen.

*When the cursor is moved over to 

 on the Web screen, the explanation is shown.

* Windows is a registered trademarks of Microsoft Corporation in the United States and/or other countries.

STEP 1

STEP 3

STEP 2

- (2) -

Password settings

User Password Settings

You can change the password for user login.

Administrator password settings

The administrator password can be changed. Make sure to change the

password from the default setting by installer from the information security

point of view. Without the initial change, there is a possibility that unspecified

users may be able to change the settings and it may result in serious

accidents. Make sure to keep the password somewhere safe.

Door position

Drag and drop the     and the      marks

on the camera image to specify the

door opening width.

Installation height

Set the height of the sensor installation

suited to the installation environment.

Sensitivity

Adjust the detection sensitivity fitting

for the installation environment.

Normally, set to [Standard].

Human body detection size

Adjust the human body detection size

suited to the installation environment.

Normally, set to [Standard].

Adjust the human recognition area

suited to the installation environment.

In normal case, specify the setting so

that the area should cover the entire

camera image. On the image, the

yellow line is displayed.

Human recognition area

eTracker area

Drag and drop the     and the      marks

on the camera image to specify the

detection area range configured (or to

be configured) for the existing

automatic door sensor.

* eTracker is a unique indicator that

shows the contribution rate to the

environment compared with the

conventional automatic door sensor,

and it can numerically indicate the

effect of the installation of this device.

To view eTracker, install the

application dedicated to smart devices,

"VVS eTracker", on your device.

Unnecessary openings due to

following conditions may be reduced

by selecting an object(s). In normal

cases it can be disabled.

Immunity

Summary of Contents for VVS-1

Page 1: ...install and set up the sensor within the range of specification Danger of getting caught in the door WARNING 1 EU declaration of conformity Hereby OPTEX declares that the radio equipment type VVS ser...

Page 2: ...pth is up to 10m 32 10 Please set according to the setting environment For details refer to Web setting manual eTracker area For details refer to Web setting manual Header sensor area For details refe...

Page 3: ...ivation output 24VDC Form A relay 50V 0 1A max Opto coupler Opto coupler Door controller side Remove the housing cover 1 Mounting plate 2 Wiring the cable to the door controller Before starting the pr...

Page 4: ...ng plate Installation Raise it upward 4 Hook Hook Fitting section Perform fitting and pull down while pressing the main body to the mounting plate Put the main body on the hook of the mounting plate S...

Page 5: ...the app Slow green blue blinking Fast green blue blinking App password reset Fast green blinking Sensor failure IP address reset indicator Smart device app This product links with the smart device app...

Page 6: ...rm up has not completed due to the setting error Use the rain cover Separately available Or wipe the camera lens with a damp cloth Or install in a place keeping the water drops off Approach to the pro...

Page 7: ...duct with LAN cables After inputting click the OK button Start up the web browser and input the IP address 192 168 0 249 at factory default of this product into the address input column The logon scre...

Page 8: ...ther countries STEP 1 STEP 3 STEP 2 2 Password settings User Password Settings You can change the password for user login Administrator password settings The administrator password can be changed Make...