Installation
STEP 14
If wiring is to be exposed, break the knockout.
Place the housing cover.
* Check that the housing cover and wiring are not interfering.
■
Do not use without the housing cover.
■ When using the cable knockout, install on the indoors or use the
rain cover (separately available) otherwise electric shock or
breakdown of the sensor may occur.
Knockout
Main body
Housing cover
Dipswitch settings
IP address reset switch
Use this switch when resetting the IP address to the default
values (192.168.0.249).
Push the switch for 2 seconds after confirming that the
product is in the stand-by status.
When the reset is confirmed, the IP address reset indicator
goes on from the blinking status.
LAN port
Perform the Web setting
through LAN connection.
For the setting method, see
the attached
Web setting
manual
.
Operation indicator
The operation status of the header sensor is displayed on the
operation indicator of the header sensor. For details, refer to
the operation manual of the header sensor.
During connecting
to the app
Slow green & blue
blinking
Fast green &
blue blinking *
App password
reset
Fast green
blinking
Sensor failure
IP address reset indicator
Smart device app
This product links with the smart device app "
VVS eTracker
", and the app can show
the contribution ratio to the environment compared to conventional sensors.
For details, refer to
VVS eTracker User guide
.
App password reset switch
Use this switch when resetting the app's
password to the default values (0000).
Push the switch for 2 seconds after
confirming that the product is in the
stand-by status.
(See [Operation indicator])
Dipswitch 1 : Warm-up output
OFF
1
ON
1
N.O.
3
N.C.
3
The Activation output during warming up (approx. 30sec.)
when just after turning on the power and changing the
web setting is adjustable. When setting to "OFF", the door
becomes the closed state, and when setting to "ON", the
door becomes the opened state. Normally, set to "ON".
*Dipswitch 2, 4 to 8 is not used.
Dipswitch 3 : Activation output
Dipswitch 3 is for the Activation output to the door
controller.
Adjustments
Warm-up
Stand-by
Detection
Green
Red
Cross traffic
cancel
Green
glimmering
Blue
glimmering
* Operation indicator is turned off after completing.