background image

Unit: mm (inch)

Unit: mm (inch)

OPTIONS

9

9-1 OPTIONS

Anti Bird Cap  ABC-4

Back Cover  BC-4

Battery Common use Unit  BCU-4

Pole Side Cover  PSC-4

Unit: mm (inch)

Unit: mm (inch)

458 (18)

470 (18.5)

84 (3.3)

199 (7.8)

85 (3.3)

458 (18)

83 (3.3)

138 (5.4)

Prevent birds and small animals from the detector to reduce 

the false alarm. 

Prevent streaming rain and snow from the front of the detector 

to keep the sensitivity.

Conceal the back side of pole mounted detector.

Conceal the gap of pole mounted detectors back to back.

Beam Alignment Unit  BAU-4

 

Adjust optical axis automatically. (receiver only)

Extension Cable with Connector  EC-4

Extend cables to the back box and the main unit when installing 
in the beam tower.

Share power source and low battery signals between the main 

unit and the wireless transmitter.

Cable length: 500 mm (19.7 inch)

84 (3.3)

55 (2.2)

26 (1.0)

16 (0.6)

317    333 (12.5    13.1)

EU contact information

Manufacturer:

OPTEX CO., LTD.

5-8-12 Ogoto, Otsu, Shiga, 520-0101 JAPAN

Authorised representative in Europe:

OPTEX (EUROPE) LTD. / EMEA HEADQUARTERS

Marandaz House 1 Cordwallis Park, Clivemont Road,

Maidenhead, Berkshire, SL6 7BU U.K.

OPTEX INC. (U.S.)

URL: http://www.optexamerica.com

OPTEX DO BRASIL LTDA. (Brazil)

URL: http://www.optex.net/br/es/sec

OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)

URL: http://www.optex-europe.com

OPTEX TECHNOLOGIES B.V. (The Netherlands)

URL: http://www.optex.eu

OPTEX SECURITY SAS (France)

URL: http://www.optex-security.com

OPTEX SECURITY Sp.z o.o. (Poland)

URL: http://www.optex.com.pl

OPTEX PINNACLE INDIA, PVT., LTD. (India)

URL: http://www.optex.net/in/en/sec

OPTEX KOREA CO.,LTD. (Korea)

URL: http://www.optexkorea.com

OPTEX (DONGGUAN) CO.,LTD.

SHANGHAI OFFICE (China)

URL: http://www.optexchina.com

OPTEX (Thailand) CO., LTD. (Thailand)

URL: http://www.optex.net/th/th

Copyright (C) 2017 OPTEX CO.,LTD.

PORTUGUÊS

DEUTSCH

IT

ALIANO

ESP

AÑOL

FRANÇAIS

ENGLISH

EN-12

Summary of Contents for Smart Line Series

Page 1: ...n the transmitter 4 in the receiver normal operation requires 2 batteries Battery saving function Intermittent output function Spacious back box for numerous wireless transmitters Quad high power beam...

Page 2: ...e unit at least 1 m 3 3 ft away from the wall or fence that may be running parallel to the beam Accessories Velcro tape 2 sets U brackets 4 Pole brackets with double sided tape 4 4 20 self tapping for...

Page 3: ...s shown For more information on wiring see 3 4 WIRING on page 7 When using battery common use unit BCU 4 option refer to the corresponding manual Use of batteries other than recommended may shorten th...

Page 4: ...the optical unit when mounting the cover Otherwise malfunction may occur due to the shift of the optical axis resulting in the need of readjustment Banding band Wiring notch Pull 7 Fix the main unit...

Page 5: ...liner 3 Perform the wall mounting procedure of 3 to 9 on page 3 to 4 3 Perform the wall mounting procedure of 3 to 9 on page 3 to 4 POLE 1 POLE 2 When mounting the single set of detectors to the pole...

Page 6: ...maximum detection range shall be half of the original detection range This is to compensate the attenuation of beam by the corner of the cover When installing the detector without the cover lock the t...

Page 7: ...common use unit BCU 4 option NOTE 3 6 WIRING Receiver Red Black Power input Power input Red Black Orange Brown Yellow White Green Blue Purple Gray Green Blue Purple Gray Low Battery output Low Battery...

Page 8: ...e stacked protection Since Receiver B may receive the infrared beam from Transmitter A select the frequencies as shown in the figure above In the figure each number in the square indicate a channel nu...

Page 9: ...ugh alignment of the horizontal angle 2 Look into the viewfinder and perform fine alignment of the horizontal and vertical angles using the alignment dial Make the settings of 1 to 4 to the lower as w...

Page 10: ...hite Yellow Orange Brown White Yellow When wireless configuration is being used which is unable to determine whether the alarm output continues setting the intermittent output function to the ON posit...

Page 11: ...Voltage reduction Blinking Operating temperature 20 C 60 C 4 F 140 F Operating humidity 95 max Alignment angle 90 Horizontal 10 Vertical Dimension H W D mm inch 452 17 9 x 83 3 3 x 138 5 4 Weight 330...

Page 12: ...500 mm 19 7 inch 84 3 3 55 2 2 26 1 0 16 0 6 317 333 12 5 13 1 EU contact information Manufacturer OPTEX CO LTD 5 8 12 Ogoto Otsu Shiga 520 0101 JAPAN Authorised representative in Europe OPTEX EUROPE...