(1) Entering Pairing mode of a Gateway Chime Unit (!VP-GU).
An IVP-GU is already set in a "Pairing mode" at the factory default setting.
To change !VP-GU into the "Pairing mode", press down both A and B buttons
and hold until LED will brink in green and red.
(2) Prepare Handheld Monitor Unit (!VP-HU) for assigning a HOME ID for !VP-GU.
Press "Paring Button" on the back of an !VP-HU and choose "SCAN" by clicking
"left function key" on the !VP-HU. The !VP-HU starts scanning for a new device.
(3) Confirming !VP-GU with a HOME ID.
When !VP-GU is assigned a new HOME ID, beeping stops and LED stops flashing to
indicate the normal operation mode.
7. PAIRING WITH OPTEX WIRELESS2000 SYSTEM
NOTE: Please configure !VP-GU before pairng WIRELESS2000 device.
To connect system to OPTEX WIRELESS2000 devices (e.g. TC-lOU)
HOME ID must be assigned to !VP-GU prior to pairing.
Gateway Chime Unit (!VP-GU) can be paired with OPTEX TC-lOU & TD-20U devices.
G�
@,
o»�
ti)
T C -lOU
TD-20U
!VP-GU
When paired with TC-lOU or TD-20U, following features are available;
- If corresponding Door Camera Unit (!VP-DU) is connected to an external
power source, TC-lOU or TD-20U can trigger an image capture from the !VP-DU.
- !VP-GU can act as an extra chime unit in WIRELESS2000 system.
7-1 Pairing TC-lOU & TD-20U to Gateway Chime Unit
One !VP-GU can host 2 units of TC-lOU or/and TD-20U, each into zone 1 and 2.
Both zone 1 and zone 2 will be associated to a Door Camera Unit (!VP-DU) which is
corresponding to the !VP-GU. In total, one system can host
4 WIRELESS2000 devices through 2 IVP-GUs.
(STEP 1) Clear/initialize !VP-GU for a new pairing of WIRELESS2000 devices
Enter into a pairing mode by holding down B button. LED starts blinking.
Select a zone by pressing B button. Hold down A button until two short beeps sound.
Repeat the same process for another zone if necessary. Exit the paring mode by
holding down B button or proceed to STEP3 if pairing immediately.
Zone 1, LED blinks slowly at 1 Hz (Green/Red)
Zone 2, LED blinks fast at 2 Hz (Green/Red)
ADDITIONAL SETTING
To change a chime volume of !VP-GU
LED (RED/GREEN)
- Press button A to acknowledge current chime volume level. Press A button again to
change volume level to the next. The volume changes within 4 levels and the lowest
volume will follow the loudest. Leave the setting at the desirable volume level.
To completely turn off the chime, set Sound ON/OFF Switch to OFF.
9-1 Dimensions
�
l
80mm/3.15"
L!!J
l!Omm / 4.33"
1---1
30.3mm/ 1.2"
1. This product is under a warranty for a normal usage for 18 months from the date
of manufacturing. The date of manufacturing can be identified from a LOT number
indicated on a label placed in a back of !VP-GU.
LOT: YYWWZ ( e.g. LOT 13502)
YY indicates last two digits of the year manufactured (e.g. "13" = Year 2013)
WW indicates Xth week of the year manufactured
(e.g. "50" = 50th week)
2. The warranty may
not be applicable
when any of following circumstances is found.
- Mechanical or electrical modification is made to the product and the good's
appearance indicates an alterations or a significant damage.
- The product is already been diagnosed by someone other than the manufacturer.
- Product malfunction is resulting from an improper usage, an accident,
natural disaster or any environmental event.
- Please call our technical assistance before arranging a return.
c:::, c:::,
1•7..:.1:: I
I!! I • 1�1
�
Handheld Monitor Unit (IVP-HU)
Pairing button
If a zone of !VP-GU already has an assigned WIRELESS2000 device, the zone will
not be overwritten and register another WIRELESS2000 device.
When pairing is denied, rapid beeps will sound.
(STEP 2) Prepare !VP-GU into a pairing mode
Enter into a pairing mode by holding down B button.
LED starts blinking. Select a zone by pressing B button.
The pairing mode continues for 30 seconds.
(STEP 3) Send pairing signal to !VP-GU
While the !VP-GU is in a pairing mode for a designated zone, trigger TC-lOU or
TD-20U to send a radio signal. !VP-GU will register the signal with a chime.
Exit the pairing mode by holding down B button.
LED stops blinking when in a normal operation mode.
NOTE: How to trigger WIRELESS2000 devices
After inserting a
battery, remove
magnet part of
the device away
from the TC-lOU.
After inserting a
battery, wave your
hand across front
of the TD-20U
TC-lOU
TD-20U
(STEP 4) Confirm operation of WIRELESS2000 devices
Trigger the paired WIRELESS2000 device. !VP-GU will blink LED and ring a chime
(Sound ON/OFF Switch must be ON). !VP-HU will also respond by a chime sound
unless a volume on !VP-HU is set to null. !VP-HU will also capture an image from
a corresponding !VP-DU if the !VP-DU is connected to an external power source.
NOTE: Low battery notification of WIRELESS2000 devices
When any paired WIRELESS2000 has a low battery condition,
!VP-GU will make a short beep following a chime sound.
Low battery beep does not sound if the sound switch on !VP-GU is set to OFF.
SENSOR ALERT mode Enable/Disable setting
- By disabling SENSOR ALERT mode, system become ignorant of connected
WIRELESS2000 devices. This setting is changed by holding "Right Function Key" on
a Handheld Monitor Unit(IVP-HU). The LED on !VP-GU indicates the current setting.
When in RED, SENSOR ALERT is Enabled.
When in GREEN, SENSOR ALERT is Disabled
9-2 Specification Table
MODEL NAME: OPTEX (!VP-GU) Gateway Chime Unit
Operating Temperature
O to 40 degC (32 to 104 degF)
Operating Humidity
< 90% RH ( no condensation)
Dust/Water Protection
N/A (Indoor Use Only)
Radiowave Frequency
2.4 GHz and 418MHz
Power
AC/DC 10-24V 3W(max)
Relay Output
lC SOVAC/24VDC lA max
REV 1.00