background image

(1) Entering Pairing mode of a Gateway Chime Unit (!VP-GU). 

An IVP-GU is already set in a "Pairing mode"  at the factory default setting. 

To change !VP-GU into the "Pairing mode", press down both A and B buttons 

and hold until LED will brink in green and red. 
(2) Prepare Handheld Monitor Unit (!VP-HU) for assigning a HOME ID for !VP-GU. 

Press "Paring Button" on the back of an !VP-HU and choose "SCAN"  by clicking 

"left function key"  on the !VP-HU. The !VP-HU starts scanning for a new device. 
(3) Confirming !VP-GU with a HOME ID. 

When !VP-GU is assigned a new HOME ID, beeping stops and LED stops flashing to 

indicate the normal operation mode. 

7. PAIRING WITH OPTEX WIRELESS2000 SYSTEM

NOTE:  Please configure !VP-GU  before pairng WIRELESS2000 device. 

To connect  system to OPTEX WIRELESS2000 devices (e.g. TC-lOU) 

HOME ID must be assigned to !VP-GU prior to pairing. 

Gateway Chime Unit (!VP-GU) can be paired with OPTEX TC-lOU & TD-20U devices. 

G� 

@, 

o»� 

ti) 

T C -lOU 

TD-20U 

!VP-GU 

When paired with TC-lOU or TD-20U,  following features are available; 

- If corresponding Door Camera Unit (!VP-DU) is connected to an external 

power source, TC-lOU or TD-20U can trigger an image capture from the !VP-DU. 

- !VP-GU can act as an extra chime unit in WIRELESS2000 system. 

7-1  Pairing TC-lOU & TD-20U to Gateway Chime Unit 

One !VP-GU can host 2 units of TC-lOU  or/and  TD-20U,  each into zone 1 and 2. 

Both zone 1 and zone 2 will be associated to a Door Camera Unit (!VP-DU) which is 

corresponding to the !VP-GU. In total,  one   system can host 

4 WIRELESS2000  devices  through 2 IVP-GUs. 

(STEP 1) Clear/initialize !VP-GU for a new pairing of WIRELESS2000 devices 
Enter into a pairing mode by holding down B button. LED starts blinking. 

Select a zone by pressing B button. Hold down A button until two short beeps sound. 

Repeat the same process for another zone if necessary. Exit the paring mode by 

holding down B button or proceed to STEP3 if pairing immediately. 

Zone 1, LED blinks slowly at 1 Hz (Green/Red) 

Zone 2, LED blinks fast at 2 Hz (Green/Red) 

ADDITIONAL  SETTING 

To change a chime volume of !VP-GU 

LED (RED/GREEN) 

- Press button A to acknowledge current chime volume level. Press A button again to 

change volume level  to the next.  The volume changes within 4 levels and the lowest 

volume will follow the loudest. Leave the setting at the desirable volume level. 

To completely turn off the chime, set Sound ON/OFF Switch to OFF. 

9-1  Dimensions 

� 

80mm/3.15" 

L!!J 

l!Omm / 4.33" 

1---1 

30.3mm/ 1.2" 

1.  This product is under a warranty for a normal usage for 18 months from the date 

of manufacturing. The date of manufacturing can be identified from a LOT number 

indicated on a label placed in a back of !VP-GU. 

LOT: YYWWZ  ( e.g.  LOT 13502) 

YY indicates last two digits of the year manufactured  (e.g. "13" = Year 2013) 

WW indicates Xth week of the year manufactured 

(e.g. "50" = 50th week) 

2.  The warranty may 

not be applicable 

when any of following circumstances is found. 

- Mechanical or electrical modification is made to the product and the good's 

appearance indicates an alterations or a significant damage. 

- The product is already been diagnosed by someone other than the manufacturer. 

- Product malfunction is  resulting from an  improper usage, an accident, 

natural disaster or any environmental event. 

- Please call our technical assistance before arranging a return. 

c:::,  c:::, 

1•7..:.1:: I 
I!! I • 1�1 
� 

Handheld Monitor Unit (IVP-HU) 

Pairing button 

If a zone of !VP-GU already has an assigned WIRELESS2000 device, the zone will 

not be overwritten and register another WIRELESS2000 device. 

When pairing is denied, rapid beeps will sound. 

(STEP 2) Prepare !VP-GU into a pairing mode 

Enter into a pairing mode by holding down B button. 

LED starts blinking. Select a zone by pressing B button. 

The pairing mode continues for 30 seconds. 

(STEP 3) Send pairing signal to !VP-GU 

While the !VP-GU is in a pairing mode for a designated zone, trigger TC-lOU or 

TD-20U to send a radio signal. !VP-GU will register the signal with a chime. 

Exit the pairing mode by holding down B button. 

LED stops blinking when in a normal operation mode. 

NOTE:  How to trigger WIRELESS2000 devices 

After inserting a 

battery,  remove 

magnet part of 

the device away 

from  the TC-lOU. 

After  inserting a 

battery,  wave your 

hand across front 

of the TD-20U 

TC-lOU 

TD-20U 

(STEP 4) Confirm operation of WIRELESS2000 devices 

Trigger the paired WIRELESS2000 device. !VP-GU will blink LED and ring a chime 

(Sound ON/OFF Switch must be ON). !VP-HU will also respond by a chime sound 

unless a volume on !VP-HU is set to null. !VP-HU will also capture an image from 

a corresponding !VP-DU if the !VP-DU is connected to an external power source. 

NOTE: Low battery notification of WIRELESS2000 devices 

When any paired WIRELESS2000 has a low battery condition, 

!VP-GU will make a short beep following a chime sound. 

Low battery beep does not sound if the sound switch on !VP-GU is set to OFF. 

SENSOR ALERT mode Enable/Disable setting 

- By disabling SENSOR ALERT mode,  system become ignorant of connected 

WIRELESS2000 devices. This setting is changed by holding "Right Function Key" on

a Handheld Monitor Unit(IVP-HU). The LED on !VP-GU indicates the current setting. 

When in RED, SENSOR ALERT is Enabled. 

When in GREEN, SENSOR ALERT is Disabled 

9-2  Specification Table

MODEL NAME: OPTEX  (!VP-GU) Gateway Chime Unit 

Operating Temperature 

O to 40 degC (32 to 104 degF) 

Operating Humidity 

< 90% RH ( no condensation) 

Dust/Water Protection 

N/A (Indoor Use Only) 

Radiowave Frequency 

2.4 GHz and 418MHz 

Power 

AC/DC 10-24V 3W(max) 

Relay Output 

lC SOVAC/24VDC lA max 

REV 1.00 

Reviews: