Page 44
Confidential
– Limited Distribution
Figure 46. Setting the second adjustable blade ringer to a safe cutting depth
Figure 47. Ring cutting the shield and foam dielectric with adjustable blade ringer tool placed on the material to
be removed
CAUTION:
The cable shield and drain wire must not contact the center conductor, which
will cause a short on the system. Be sure after stripping the dielectric that the shield has
not been compressed toward touching the center conductor.
Step 11
Trim center conductor using the coaxial cable cutter,
, to 45 mm (1.77 in) from