background image

Preface

Installation

Troubleshooting

Specifications

23

Distribution of source code for open source software

This product includes open source software.
We can copy and distribute the source code of the software according to the license requirements if the open source software includes LGPL (GNU 
LESSERGENERAL PUBLIC LICENSE) or other licenses under the conditions of disclosure.
Regarding the open source code of this product, we will distribute the source code corresponding to the open source software at the actual cost 
for at least 3 years after purchasing it to the individual/group who made the inquiry.

Contact: OPTEX OSS information desk
E-mail: [email protected]

This product contains various open source software to which the following license information applies.

arduino-esp32

GNU Lesser General Public License v2.1

AsyncElegantOTA

MIT License

AsyncTCP

GNU Lesser General Public License v3.0

CRC

MIT License

ESPAsyncWebServer

GNU Lesser General Public License version 2.1

ESPAsyncTCP

GNU Lesser General Public License v3.0

jQuery 3.6.0 min

MIT License

Dimensions

 

„

OA-607 T and loop harness

10 7/8” (276)

1 5/8”

(42)

1 1/2” (38)

1/2” (12.8)

[inch(mm)]

2 1/4” (56.9)

1 5/8”  (41.3)

1 5/16” (33.2)

(12 1/2” (318.25))

 

„

OC-907C T

4 5/8" (117)

1" (25)

2 1/2" (63)

[inch(mm)]

Summary of Contents for ELITE PRO

Page 1: ...r to the sensor system 2 Do not install the sensor where it might be directly sprayed with rainwater 3 Verify proper wiring prior to applying power to the sensor system to prevent damage to equipment 4 When setting the sensor s area pattern make sure there is no traffic around the installation site 5 Do not attempt to rebuild or repair sensor heads or control unit Contact the address in this manua...

Page 2: ...d OA 607 T 2 ELITE PRO2 Package of OC 907C T 1 and OA 607 T 4 ELITE PRO LE Package of OC 907C T 1 and OA 607 T 1 Door type and connection pattern support are as below For single swing door Full energy doors Connection pattern OA 607 T OA 607 T OC 907C T Loop harness Model name ELITE PRO Low energy doors Connection pattern OA 607 T OC 907C T Loop harness Model name ELITE PRO LE For double swing doo...

Page 3: ...op with concealed wiring 1 type For door loop with exposed wiring The longer 2 4 type is intended for stan dard concealed wiring applications The shorter 1 type is intended for ex posed wiring applications wiring exposed rather than embedded from the jamb cover within the jamb 6 I O harness Signal line between OC 907C T and door controller 12 pole cable Signal line for connection between door cont...

Page 4: ...er Activation output Stall output Knowing act input Motor BG input Close switch input indicator No Name 1 Reset switch 2 Dipswitches 3 Operation indicator 4 Interface indicator From the top knowing act input activation output stall output BodyGuard motor voltage input close switch input 5 Wi Fi status indicator 6 Sensor connector 7 Door controller connector 8 Power connector No Name 1 Connector 2 ...

Page 5: ...7C T and connecting the loop harness Connect the loop harness connector to the OC 907C T Step 4 Connecting the door front back OA 607 T Step 5 Setting the OA 607 T threshold area angle screw and swing area angle screw Step 7 OC 907C T and door controller I O wiring and OC 907C T power wiring Prepare the tools required in advance Example 1 2 3 4 5 6 7 8 1 1 Phillips head screwdriver 2 2 Phillips he...

Page 6: ...or approach side to install the door loop on 2 Positioning the door template Position the template edge at the door edge Door template R If through holes need to be drilled door front back through hole Since the holes here are penetrated on both sides the height of the both templates should be roughly adjusted Position the door template end at the door end The door front back through hole position...

Page 7: ...607 T sensor head 10 Position OA 607 T on the other side of the door as well Step 3 Installing the door loop only on the door loop mounting door side 1 Paste the jamb cover template on the jamb Template for jamb cover 2 Drill two 1 8 3 2 mm mounting holes in the jamb for the jamb cover in accordance with the template For concealed wiring drill an additional 3 8 10 mm cable exit hole in the middle ...

Page 8: ...oop cover Door loop cover Wind loop harness around Loop harness Wind the harness around the door loop cover until it matches the length here NOTE NOTE As in the figure at right wrap the loop harness around the door loop cover to adjust its length 7 Fasten the door loop cover securely to the door leaf with two Black mounting screws 2 Black Fasten the door loop cover with two mounting screws 8 Conne...

Page 9: ...f the detection angle needs to be changed see Detection area adjustment Step 6 Fitting the cover on OA 607 T 1 Put the cover on from above and fit it in Notch Pass the loop harness through the notch on the cover side Be careful not to disconnect the cable with the cover 2 Install the remaining sensors similarly Step 7 OC 907C T and door controller I O wiring and OC 907C T power wiring 1 Connect I ...

Page 10: ...utput 3 None 4 None 5 Stall output Green Output Form A or B relay 50 V 0 3 A resistance load Set form A or B with the setting app When setting N O At power OFF Close At stand by Open At detection Close When setting N C At power OFF Close At stand by Close At detection Open 6 Stall output Green Output 7 Test input Pink Input Optocoupler voltage 5 to 30 VDC current 6 mA max 30 VDC no polarity 8 Test...

Page 11: ...or all wiring Purple Red Yellow Green Pink White OR PUSH TO OPEN Push plate Knowing act input Relay 1 output Relay 2 delayed output Time delay module Electric lock Knowing act device e g Push plate Door controller Test output Stall input Activation input Close switch input Motor 1 2 OA 607 T OA 607 T Knowing act signal 1 Do not wire for not monitored door 2 How to connect Motor BG input Red wire R...

Page 12: ...07 T OA 607 T Door controller Test output Stall input Activation input Close switch input Motor 1 2 Purple Knowing act signal OR Push plate PUSH TO OPEN Knowing act signal Red Yellow Green Pink White Knowing act input Relay 1 output Relay 2 delayed output Time delay module Electric lock Knowing act device e g Push plate OA 607 T OA 607 T Door controller Test output Stall input Activation input Clo...

Page 13: ...indicator z Operation indicator Procedures Color Indicator diagram Status Meaning Before initial setup Orange Blinking 0 5 s intervals Configuration error within setting error During initial setup Orange Blinking fast 0 1 s intervals Auto configuration start Green Solid Auto configuration normally completed stand by Orange Blinking 0 5 s intervals Auto configuration abnormally completed During aut...

Page 14: ...ial setup Orange Blinking fast 0 1 s intervals Auto configuration start Green Solid Auto configuration normally completed Orange Blinking 0 5 s intervals Auto configuration abnormally completed During auto area learn See Automatic settings and auto area learn During normal oper ation Green Solid Door fully closed Orange Solid Door closing Red Solid Door fully closed Red Blinking fast 0 1 s interva...

Page 15: ...er dipswitch 2 Wi Fi setting to ON using Wi Fi communication and set from the setting app OC 907C T For setting OC 907C T use the dipswitch or the setting app Reset switch 2 s press Reset password after 2 s the operation indicator will turn off and return to normal operation 10 s press Reset settings to factory defaults after 10 s the operation indicator will turn off and return to normal operatio...

Page 16: ...Meaning Green Blue Blinking among colors 0 5 s intervals Sensor setting via Wi Fi OC 907C T operation indicator Color Status Indicator diagram Meaning Green Blue Blinking among colors 0 5 s intervals Sensor setting via Wi Fi Screenshots are under development Actual specifications may vary Setting items Items Value Dipswitch setting possible OA 607 T dipswitch OC 907C T dipswitch 1st row sensitivit...

Page 17: ...TION Adjust the areas in accordance with ANSI 156 10 5 5 0 Threshold area 1st row Swing area 2nd 3rd row Side view When both threshold area and swing area are 5 When both threshold area and swing area are 5 When both threshold area and swing area are 0 Sensor pattern H J L N B C D E F G I K M O A Threshold area 1st row Swing area 2nd 3rd row Value dimensions for each door angle feet mm Door angle ...

Page 18: ... s intervals Auto configuration start Execute auto configuration The door will open and close two or three times automatically 1 Solid Green after normal completion Setup complete stand by Upon failure after checking the wir ing execute auto configuration again If there is no problem with the wiring manual setting from a smart device is also possible After installation is complete leave the power ...

Page 19: ...n detection area to ensure proper operation 2 Always keep the detection window clean If dirty wipe the window with a damp cloth do not use any cleaner or solvent 3 Do not wash the sensor with water 4 Do not disassemble rebuild or repair the sensor yourself otherwise electric shock may occur 5 Contact your installer or the sales engineer if you want to change the settings 6 Do not place an object t...

Page 20: ...utput Green wire test input Pink wire BodyGuard or motor voltage input Red wire close switch input White wire 3 Connected with sensor cable but communication is unstable Sensor cable may be disconnected or connector insertion may be loose z OC 907C T operation indicator Operation indicator Left corresponds to left side connector and right to right side connector Procedures Color Indicator diagram ...

Page 21: ...of installations stopping after first activation means system is OK OA 607 T sensor head not mounted flush on door Head may be resting on top of door loop cover reposition head flush on panel Improper threshold or swing area angle adjustment Set threshold and swing area angles at 5 degrees Deep Motor voltage input BodyGuard input or close switch input is unsuitable Refer to Wiring and connect moto...

Page 22: ... go to stand by OC 907C T indicators blinking Or ange twice communication error More than two OA 607 T have been con nected per door Refer to Wiring and connect OA 607 T suitably Loop harness or pass through harness is disconnected Replace as necessary OC 907C T OA 607 T indicators blinking Blue OC 907C T dipswitch setting is incorrect Check OC 907C T dipswitch setting OA 607 T indicator is blinki...

Page 23: ... for at least 3 years after purchasing it to the individual group who made the inquiry Contact OPTEX OSS information desk E mail oss distribute optex co jp This product contains various open source software to which the following license information applies arduino esp32 GNU Lesser General Public License v2 1 AsyncElegantOTA MIT License AsyncTCP GNU Lesser General Public License v3 0 CRC MIT Licen...

Page 24: ...rence that may cause undesired operation Le présent appareil est conforme à la partie 15 des règles de la FCC et aux normes des CNR d Innovation Sciences et Développement économique Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l appareil doit accepter tout brouillage subi mê...

Reviews: