![Optex ELITE PRO Instruction Manual Download Page 12](http://html1.mh-extra.com/html/optex/elite-pro/elite-pro_instruction-manual_1640894012.webp)
Preface
Installation
Troubleshooting
Specifications
12
• Wiring example for double swing door
OR
Push plate
PUSH
TO OPEN
Polarity free for all wiring
Polarity free for all wiring
Door 1
Door 2
Power 12 to 30 VDC
(Polarity free)
OC-907C T
Purple
Red
Yellow
Green
Pink
White
Knowing
act
input
Relay 1
output
Relay 2
delayed
output
Time delay module
Electric
lock
OA-607 T
OA-607 T
Door controller
Test output
Stall input
Activation input
Close switch input
Motor
*1
*2
Purple
Knowing act
signal
OR
Push plate
PUSH
TO OPEN
Knowing act
signal
Red
Yellow
Green
Pink
White
Knowing
act
input
Relay 1
output
Relay 2
delayed
output
Time delay module
Electric
lock
Knowing act
device
(e.g. Push plate)
OA-607 T
OA-607 T
Door controller
Test output
Stall input
Activation input
Close switch input
Motor
*1
*2
Knowing act
device
(e.g. Push plate)
*1 Do not wire for not monitored door.
*2 How to connect Motor/BG input. (Red wire)
Red
Door controller
Motor