Set the Option Module switches as required. Refer to the Option Module manual for details on setting the
switches.
8.
Reassemble in the reverse order. Do not over tighten the screws..
F
IGURE
3
—
9245DT
BUILT-IN PTZ/DATA CHANNEL SWITCH SETTINGS AND CONNECTIONS
The PTZ data channel switch sets the data Input and output formats. Refer to Table 1 and the Input/Output
connection diagrams below set and connect data signals.
TABLE 1 — 9245D DIPSWITCH SETTINGS
Type/Switch
Position
1
2
3
4
5
6
7
8
9
10
RS232
ON
(DOWN)
OFF
(UP)
OFF
(UP)
OFF
(UP)
OFF
(UP)
N/A
N/A
OFF
(UP)
ON
(DOWN)
OFF
(UP)
RS422
OFF
(UP)
OFF
(UP)
ON
(DOWN)
ON
(DOWN)
ON
(DOWN)
T
T
ON
(DOWN)
OFF
(UP)
ON
(DOWN)
RS485 2-Wire
ON
(DOWN)
ON
(DOWN)
OFF
(UP)
ON
(DOWN)
ON
(DOWN)
T
T
ON
(DOWN)
OFF
(UP)
ON
(DOWN)
RS485 4-Wire
OFF
(UP)
ON
(DOWN)
OFF
(UP)
ON
(DOWN)
ON
(DOWN)
T
T
ON
(DOWN)
OFF
(UP)
ON
(DOWN)
Manchester
ON
(DOWN)
ON
(DOWN)
ON
(DOWN)
OFF
(UP)
OFF
(UP)
T
T
ON
(DOWN)
OFF
(UP)
ON
(DOWN)
Disabled
OFF
(UP)
OFF
(UP)
OFF
(UP)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Notes
¹ N/A Switch position does not affect setting.
2
T = Input Termination Setting, ON = Termination On, OFF = Termination Off.
Terminations should be on for the last RS422 and RS485 input where five or fewer inputs
are connected in parallel.