background image

 

 
 

2.4 

Construction 

 

Generator consist of modules connected together by DIN and/or AWP connectors. 

 

• 

main board  

• 

supply board 

• 

suppressor board  

• 

analog and digital signals controlling board 

• 

PWM board 

• 

filters board 

• 

power stage board 

• 

measurement board 

• 

RS 232 communication control board 
 

2.5 

 

Information plate 

 

 

  

www.optel.pl 

Power Ultrasound Generator 

UG S/A 

 

Serial no.: 07.12.rev.4 

Date of production.: 03.2008 

 

 

Ultrasound Frequency: 17 – 50kHz 

 Power Supply: 220-240 VAC/50Hz 
 Power Output: 600W 
 Dimensions: 360 x 340 x 160mm 
 Weight: app. 11 kg 
 Standard: 67/308/Ce 

 

 

Fig. 2. Information plate 

 

2.6 

 

Technical information 

 

• 

frequency range: 

 

 

 

 

17 000 - 50 000Hz 

• 

frequency setting resolution: 

 

 

1Hz or 2Hz  

• 

maximum output power: 

 

 

 

max 600W 

 

maximum output voltage:   

 

 

500V

sk 

 

maximum output current:   

 

 

4.0 A

sk 

• 

output voltage shape: 

 

 

 

SIN (h max. < 10% )  

• 

accuracy of frequency measurement:  

 

±

1Hz 

• 

accuracy of voltage measurement:  

 

±

5%, 

±

5 LSB 

• 

accuracy of current measurement:  

 

±

5%, 

±

5 LSB 

• 

accuracy of phase measurement:   

 

±

2

°

 (in range +50/-70

°

• 

accuracy of  absolute value of  

o  impedance measurement:    

 

±

5% (in range 20-400

• 

four temperature sensors:   

 

 

PT100 

• 

load impedance (minimum): 

 

 

40-300

1

  

• 

supply  

 

 

 

 

 

230 VAC / 50Hz 

• 

maximum output power: 

 

 

 

600W 

• 

PC communication protocol:  

 

 

RS232 

• 

three parts of load impedance range 

 

• 

adjustable output voltage in range:   

 

1%-99% (with 1% resolution) 

• 

transformer output 

Summary of Contents for UG - S/A

Page 1: ...dukcyjne OPTEL Sp z o o ul Morelowskiego 30 PL 52 429 Wrocław tel 48 071 329 68 54 fax 48 071 329 68 52 e mail optel optel pl http www optel pl Wrocław 03 11 2009 ULTRASONIC GENERATOR UG S A rev 4 0 03 07 2008 Technical Documentation ...

Page 2: ...ustomer has the right to request for unpaid repair All defects should be reported to the manufacturer Warranty period is extended by number of days needed to repair device which are counted from delivery to manufacturer to send off day In case of any failures repairs are made only by manufacturer the repairs are free of charge if failures are caused by manufacturer and if warranty period hasn t ex...

Page 3: ...nd matching impedance 1 Frequency of the output signal could be changed in range 18 22kHz with 1Hz maximum resolution This range depends on device version and it is possible to obtain larger 15 60kHz Output signal is based on quartz generator 2 Maximum output power is 500W and it is regulated by change output voltage This is done by driving power stage by PWM signal Pulse width is defined as ratio...

Page 4: ... Fig 2 Information plate 2 6 Technical information frequency range 17 000 50 000Hz frequency setting resolution 1Hz or 2Hz maximum output power max 600W maximum output voltage 500Vsk maximum output current 4 0 Ask output voltage shape SIN h max 10 accuracy of frequency measurement 1Hz accuracy of voltage measurement 5 5 LSB accuracy of current measurement 5 5 LSB accuracy of phase measurement 2 in...

Page 5: ...2 adapter Microsoft Windows operating system 95 98 ME 2000 XP VISTA and dedicated software UG S A rev 2 0 which is distributed with this product Content of CD DVD where ug_sa pdf UG S A technical documentation setup exe ug_sa msi software installer DistFile cab instmsi exe instmsiw exe setup ini installer files Auxiliary supply 5V 12V Frequency synthesis device µC Adjustable PWM supply Power stage...

Page 6: ...Power power ON OFF switch Iout diagnostic current output Uout diagnostic voltage output Fig 5 Back panel 1 Power connector 2 Glass body fuse 5x20mm 6 3A 250V quick acting 3 RS232 interface DB9 female 4 Output connector for ultrasound transducer 5 Fan Do not cover the fans this may damage the generator 3 2 Guidelines for user Before power ON please check ...

Page 7: ... the generator must be turned off exit the program F10 turn off the PC turn off the device and disconnect mains cable Replace the fuse only with identical one see the description below the fuse socket glass body 5x20mm 6 3A 250V quick acting WARNING FAILURE TO FOLLOW THESE RULES MAY CAUSE SERIOUS INJURY OR DEATH The user is responsible for any damages or injuries caused by the improper use of the ...

Page 8: ..._f analizer_m set protocol ug_sa exe lissa uir 3 4 Software description After starting UG S A software main panel appears on the screen It is shown below Fig 6 Main panel Main panel consist of following elements ...

Page 9: ...l is used to set generation parameters power and frequency UG S A software allows the generator to work in two modes automatic or manual frequency setting In automatic mode the generator automatically adjusts to the resonance frequency of the transducer and keeps it In manual mode user sets desirable frequency Generator condition panel Below the main panel is located a status bar of RS232 port whe...

Page 10: ...ons There are two ways of using function buttons User may click on them using the mouse or use function buttons on his keyboard F1 F10 Button Description Function F1 START STOP Start acquisition and generation on the output F2 Open Load settings from file F3 Save Save actual settings to file F4 F5 Characteristic Enter analyzer window F6 Service Enter the service panel F7 Print Print screen F8 Unit...

Page 11: ...1 Fig 8 Main panel connection with UG S A failed Fig 9 Main panel generator works properly ...

Page 12: ...ring work the user may change voltage and frequency if power voltage or current exceed the maximum permitted level generator is stopped as STOP F1 Measuring load frequency response To measure load frequency response click Characteristic F5 button on main panel From that time device works as analyzer Fig 10 Characteristic panel ...

Page 13: ...ion and generation on the output characteristic plotting F2 Open Load settings from file F3 Save Save actual settings to file F5 Display P W Power graph in frequency domain F6 Z f P W Impedance graph in power domain F8 Print Screen Print screen F9 About us Information about manufacturer F10 Back Back to the main panel If you click START F1 button for chosen range and frequency with declared interv...

Page 14: ...be difficult to realize In this mode generator changes frequency in range selected by cursor In the left on the bottom of the window there is shown a table with measured values User could choose any of them by selecting by the cursor It is possibility to archive measured data 2nd part voltage current power impedance and phase There are creating files in Excels format phase filename_____fi csv curr...

Page 15: ...elected range of output voltage and with selected intervals After scan started generator is changing Out Voltage Level with declared step and with declared time intervals Delay s on the graph there are printed out impedance and power values In the lower left window is shown table with measured values The user may set desirable range of X and Y axes Range Also there is possibility to save measured ...

Page 16: ...anufacturer F10 Back Back to the previous panel Additional information Clicking on colored windows user may choose the color of the background grid or plot The company registered in the Companies Register by the Regional Court Wroclaw Fabryczna 4th Industrial Section of the National Court Register under KRS number 0000124439 NIP PL8981047033 REGON 008375538 The amount of the capital equals 364 500...

Reviews: