Hot Water Boiler Manual – Models H 635, H 650 

Fig. 2: Selected spare parts for H 635 & H650 boilers 

 

 

Short fire bar 

 

 

Refueling, ashtray and 
cleaning doors 

 

Long fire bar 

 

 

Grate bracket 

 

Swivel support of long 
fire bars 

 

 

Firing flap 

 

Swivel support of short 
fire bars   

 

 

 

Ash tray 

 

Underburning / through-
burning flap 

 

 

 

Refractory panel 

 

Firing flap lever 

 

 

 

 
 

F)  Instructions for use 

  

Boiler firing 

 
The  boiler  shall  be  fired  as  an  ordinary  stove.  Place  paper  to  the  grate  through  the  top  door  and  cover  with 
kindling. Add  several  bigger  pieces  of  wood. Close the secondary air supply using lever located on the side of 
the  boiler.  Moving  the  lever  backwards  closes  the  air  supply,  while  moving  the  lever  forward  will  open  the  air 
supply. 
 
Move the grate backwards, ignite a piece of paper and put it under the grate through a gap formed after moving 
the  grate.  Move  the  grate  to  a  neutral  position  after  ignition. Add  wood  and  other  fuel  as  needed  until  the  fuel 
level  exceeds the lower edge of the underburning partition. Then charge such quantity of fuel which will fill the 
charging shaft up to the level ensuring a tight closing of door. The quantity of fuel added shall not cause tipping 
of the underburning / through-burning flap.  
 
Lignite  shall  be  burned  by  underburning,  i.e.  the  underburning  /  through-burning  flap  is  in  the  upright  position. 
Tipping  of  this  flap  is  carried  out  by  a  hook  which  shall  be  engaged  with  an  eye  welded  to  the  firing  flap  after 
opening the charging door.  
 
In case of a low chimney effect during firing we may open the firing flap. This is performed by moving the weight 
backwards. Immediately after thorough ignition of fuel is reached move the flap towards the front section of the 
boiler  by  moving  the  weight. Keep the flap open for a shortest time possible, since the flue gases do not pass 
through  the  heat-exchanging  segmented  surface,  but  directly  to  the  chimney  when  the  flap  is  open  and  this 
causes heat losses and uneconomical operation. 
 

Summary of Contents for H 635

Page 1: ...ting of supplied accessories 4 E Listing of replaceable spare parts 4 F Instructions for use 5 G Maintaining the boiler and heating equipment 6 H Safety instructions for installing and using the boile...

Page 2: ...y effect considerably g The large volume ashtray compartment allows a long term operation with no need of the frequent ash removal B Technical description The boiler the height of which is 1 606 mm fo...

Page 3: ...l Parameter Unit H 635 H 650 Operating flue mbar 0 25 0 3 Water volume l 80 110 Smoke flue diameter mm 160 160 Hydraulic loss of the boiler T 20 10 mbar 0 7 0 2 0 07 0 2 Boiler class 1 1 Burning time...

Page 4: ...7 Instruction manual E Listing of replaceable spare parts Component Pieces 1 Cleaning door 1 pc 2 Refueling door 1 pc 3 Ash tray door 1 pc 4 Firing flap 1 pc 5 Underburning through burning flap 1 pc 6...

Page 5: ...er ignition Add wood and other fuel as needed until the fuel level exceeds the lower edge of the underburning partition Then charge such quantity of fuel which will fill the charging shaft up to the l...

Page 6: ...r using scraper Impurities fall through the rear section of segments onto the fire bridge From there they move through the burning shaft into the ashtray compartment This shaft can be cleaned through...

Page 7: ...release Individual pipes of the smoke flue shall be slid into each other with at last 80 mm overlap We recommend that the distance from the boiler to the chimney be less or equal to 1 m The smoke flu...

Page 8: ...appliance shall be used in compliance with instructions provided in this manual The boiler may be left unattended provided that the output is set to a level when overheating of the system cannot occur...

Page 9: ...Each heating system shall be fitted with at least one safety valve positioned on the discharge pipe or on the boiler and the pressure gauge Location installation and inside diameter of the safety valv...

Page 10: ...fference determined for steel boilers at 50 kPa P1 Absolute value of the hydrostatic pressure kPa V Increased volume of water in the whole system dm 3 V G v Where G Weight of water in the heating syst...

Page 11: ...rheating is avoided As soon as water in the boiler cools down the valve starts closing automatically and the cold water supply to the safety exchanger is closed completely after all This activity may...

Page 12: ...Hot Water Boiler Manual Models H 635 H 650 12 Boiler connection Reservoir for TS 130 Cooling water discharge valve sensor Honeywell TS 130 valve from the cooler...

Page 13: ...n 4 Firing flap 5 Underburning through burning flap 6 Long fire bar 7 Short fire bar 8 Grate mechanism 9 Long fire bar support 10 Short fire bar support 11 Fire clay panel 12 Ash tray 17 Burner hole p...

Page 14: ...4 View of the boiler 1 Cleaning door 2 Refueling door 3 Ashtray door 13 Firing flap lever 14 Grate control lever 15 Secondary air lever 16 Firing flap 19 Pressure gauge 20 Filling and discharge valve...

Page 15: ...on Primary air inlet Primary air Fig 5 Boiler section during firing 1 Open the firing flap 2 The underburning through burning flap can also be set to through burning 3 Set the flap to underburning bef...

Page 16: ...ion fuel underburning The underburning method is used for the following fuel types Lignite Anthracite Small wooden waste Close the firing flap immediately after a proper burning is obtained and set an...

Page 17: ...sh as household refuse Metal parts are to be given over in a junk storage place After termination of the product operating life cover and grates shall be liquidated as metal waste insulation material...

Page 18: ...Phone 420 571 675 589 Fax 420 571 611 225 Shipping date EXW _____________________ Warranty conditions This warranty certificate provides a proof of quality and completeness The manufacturer confirms t...

Page 19: ...for 60 months from the EXW shipping date This guarantee is subject to the fact that the pressure expansion vessel has not been used in the heating system and leakage was caused by the inferior quality...

Page 20: ...is impossible to proceed as per point a the manufacturer is entitled to specify the method date and performance of the repair by its service personnel or contractual partner c The user shall allow the...

Page 21: ...en v hody je pot ebn vyplnit registra n kartu a zaslat ji na na i adresu OPOP spol s r o Obchodn odd len Za ovsk 750 757 01 Vala sk Mezi Po obdr en vypln n ho formul e V m obratem za leme Z kaznickou...

Page 22: ...441 T 58 5341826 603 993849 LITOVEL 22 Ku m n Josef M n k 3 B la Lhota T 58 5340503 737 583317 LITOVEL 23 Svoboda Ji Havl kov 996 T 326 323779 604 942834 MLAD BOLESLAV 24 Mixed Velebudice Stavba 39 T...

Reviews: