25
Instruction manual
| RX 5 T
25
9. Changing dosage / 10. LED Function
9. Changing dosage
The dosage can be varied by selecting one, two or three strokes per activation. If set for multiple strokes
the dispenser will only operate as long as a hand is present. If the hand is removed it will complete the
current activation and then stop the dispenser.
The dispenser is supplied, set to single stroke as standard.
With the faceshield open press the tab (see 7.2) (left hand side) to increase the number of strokes.
The LED will flash amber when the tab is pressed correctly.
Pressing the tab
Number of flashes Number of strokes
1st time
2 flashes
2 stroke
2nd time
3 flashes
3 stroke
3rd time
1 flash
Returns to 1 stroke
Colour
Explanation
RED (Continuous) Faceshield open/not closed correctly
RED (Flashing)
Batteries low
Green
Unit dispensing
Amber
Stroke selection (based on number of flashes)
10. LED Function
Underneath the faceshield there is an LED which lights green, red and amber.