72
Managing Operators and Jobs
Model 72™ Operator Manual
OPEX Corporation
5.4.5. VERIFIER OPTION
The
VERIFIER OPTION
screen (Figure 5-29) has three modes.
Figure 5-29: Verifier Option screen
Use the arrows to set the Verifier and push
Enter
to save your setting.
•
VERIFIER OFF
: No checking of the envelope will be made in this mode. This
setting is good for jobs with large variations in thickness between
envelopes.
•
USE FIRST ENVELOPE AS REFERENCE
: This allows the first envelope to set
the standard for each envelope that follows.
•
USE 16 ENVELOPE AVERAGE AS REFERENCE
: This uses a floating average of
the previous 16 envelopes as the reference. This mode allows for minor
variations in envelope thicknesses.
Verifier Voltage Change
This parameter can be used to “fine tune” how the verifier is sensing empty
envelopes. Use the on-screen instructions to set the verifier to its optimal
setting (Figure 5-30).