Opes OP-WS01/WH1170 Instruction Manual Download Page 8

 

 

- 8 - 

b. The alarm will reactivate automatically once the value has fallen below the set value, or if a new value is 
entered. 
 

 
The outdoor weather alarm   

When a set outdoor weather alarm has been triggered, it will flash on the LCD display and the general 
outdoor alarm icon and high/low alarm icon will flash accordingly. For example in outdoor temperature 
display mode, when dew point high alarm is triggered, 

DEW POINT

 icon will flash along with general 

outdoor alarm icon and high alarm icon telling that the current alarm source is from dew point. 

 

 

 

 

 

 

5.4 Min/Max Mode 

 

-

 

While  in  Normal  Mode,  press  the 

MIN/MAX

  key  to  enter  the  maximum  mode, 

MAX

  logo  and  the 

general Max record will be displayed. 

-

 

Press

  MIN/MAX

  key  again  to  enter  the  minimum  mode, 

MIN

  icon  and  minimum  record  will  be 

displayed   

-

 

Press 

MIN/MAX

 key again to return the Normal Mode 

 

-

 

Maximum Reading Reset: In the maximum reading Mode, press the 

+

 key to display the maximum 

values for the readings below together with the time and date time stamp at which these values were 

recorded

. Press 

SET

 key for 2 seconds for each reading to reset the Maximum value to the current reading: 

 

 

1.  Indoor humidity maximum 

2.  Indoor temperature maximum 

3.  Outdoor humidity maximum 

4.  Outdoor temperature maximum   

5.  Outdoor dew point maximum 

6.  Pressure maximum 

 

-

 

Minimum  Reading  Reset:  In  the  minimum  reading  Mode,  press  the 

+

  key  to  display  the  minimum 

values for the readings below together with the time and date at which these values were recorded. 

Press 

SET

 key for 2 seconds for each reading to reset the Minimum value to the current reading:   

1.    Indoor humidity minimum 

2.    Indoor temperature minimum 

3.    Outdoor humidity minimum 

4.    Outdoor temperature minimum   

5.    Outdoor dew point minimum 

6.    Pressure minimum 

Summary of Contents for OP-WS01/WH1170

Page 1: ...4 4 Examples of changing weather icons 5 4 5 Storm warning indicator 5 5 Program modes 5 5 1 Quick display mode 5 5 2 Setting mode 6 5 2 1 Setting Calibrated Humidity 6 5 2 2 Setting Barometric Pressu...

Page 2: ...he temperature from its location Every time the remote sensor is powered up for example after a change of batteries a random security code is transmitted and this code must be synchronized with the ba...

Page 3: ...at designated disposal points Never dispose of batteries in a fire as this may cause explosion risk of fire or leakage of dangerous chemicals and fumes 3 2 Mounting 1 Base station By using the foldab...

Page 4: ...unit 12 Indoor temperature and humidity alarm on indicator 13 Remote sensor transmit signal indicator 14 MIN MAX information 15 Dew point temperature display 16 Outdoor humidity display 17 Outdoor te...

Page 5: ...suit the user s requirement for storm forecasting from 3 9hPa default 4hPa When there is a fall over pressure threshold within 3 hours the storm forecasting will be activated the clouds with rain icon...

Page 6: ...solution loss due to its internal calculation algorithm 5 2 1 Setting Calibrated Humidity The display console allows you to calibrate both the indoor and outdoor humidity Humidity is a difficult param...

Page 7: ...layed only for those already activated all other not activated values will be displayed with or instead Press the ALARM key again to return the Normal Mode In the High Alarm Mode press the SET key to...

Page 8: ...will be displayed Press MIN MAX key again to return the Normal Mode Maximum Reading Reset In the maximum reading Mode press the key to display the maximum values for the readings below together with...

Page 9: ...ange batteries Temperature humidity or air pressure is incorrect Check replace batteries If multiple remote sensors are in use check location with corresponding boxed numbers Or move away from sources...

Reviews: